Oxygenator safety evaluation: a focus on connection grip strength and arterial temperature measurement accuracy.

نویسندگان

  • Richard F Newland
  • Robert A Baker
  • Andrew J Sanderson
  • Sigrid C Tuble
  • Phil J Tully
چکیده

This report describes the assessment of three specific safety-related specifications in the consideration of an alternate oxygenator; first the grip strength relationship between various oxygenator connectors and SMARxT tubing, second, the grip strength of various biopassive tubings and an isolated SMARxT connector, and finally, the accuracy of the arterial outlet temperature measurement. Grip strength experiments for the connections between the SMARxT tubing and the venous reservoir outlet and the oxygenator venous inlet and oxygenator arterial outlet of the Medtronic Affinity, Sorin Synthesis, Sorin Primox, and Terumo Capiox RX25 oxygenators were performed. In addition we compared the grip strength of polyvinyl chloride, Physio, Trillium, Carmeda, X-Coating, and SMARxT tubing. The accuracy of the integrated arterial outlet temperature probes was determined by comparing the temperatures measured by the integrated probe with a precision reference thermometer. Connector grip strength comparisons for the evaluation oxygenators with SMARxT tubing showed significant variation between oxygenators and connections (p = .02). Evaluation of the arterial outlet showed significant variation between evaluation oxygenators, while at the venous reservoir outlet and oxygenator inlet, there were no significant differences. Grip strength comparison data for the various tubing types demonstrated a main effect for tubing type F(5, 18) = 8.01, p = .002, eta(p)(2) = .77. Temperature accuracy measurements demonstrated that all oxygenators overread the arterial outlet temperature at 15 degrees C, whilst at temperatures > or = 25 degrees C, all oxygenators underread the arterial outlet temperature. The integrity of SMARxT tubing connection is influenced by the connector type, and may decline over time, highlighting the importance to not consider interchanging components of the bypass circuit as inconsequential.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of temperature measurement in the cardiopulmonary bypass circuit.

Oxygenator arterial outlet blood temperature is routinely measured in the cardiopulmonary bypass (CPB) circuit as a surrogate for the temperature of the arterial blood delivered to sensitive organs such as the brain. The aim of this study was to evaluate the accuracy of the temperature thermistors used in the Terumo Capiox SX25 oxygenator and to compare the temperature measured at the outlet of...

متن کامل

Investigating the effect of sport and using anti-vibration gloves on the grip strength of workers exposed to the hand-arm vibration

Introduction: Long-term exposure to hand-arm vibration causes musculoskeletal disorders mainly in hand and shoulder. The purpose of this study was to determine the effect of sport and using anti-vibration gloves on the grip strength of workers exposed to the hand-arm vibration. Material and Methods: In this descriptive-interventionist study, 41workers working in one of the Isfahan metal indust...

متن کامل

Oxygenator evaluation: Maxima 1380 versus Maxima Plus.

Continual improvement of oxygenators has been important in the growing demands of patient safety and support during cardiopulmonary bypass. The purpose of this study was to compare the Maxima 1380 oxygenator to the upgraded Maxima Plus oxygenator. Thirty-two adult patients were randomized to either the 1380 group or the Plus group. Information was recorded on the patients' weight, age, body sur...

متن کامل

Evaluation of nutritional status of hemodialysis patients by hand grip strength

Introduction: Malnutrition (MN) is a typical complication among hemodialysis patients which is associated with morbidity and mortality rates. This cross-sectional study investigated different indices in detecting MN in hemodialysis patients. Materials and Methods: MN assessment was performed using subjective [Subjective Global Assessment (SGA) and Dialysis Malnutrition Score (DMS)] and objectiv...

متن کامل

Temperature inaccuracies during cardiopulmonary bypass.

Cerebral hyperthermia caused by perfusate temperature greater than 37 degrees C during the rewarming phase of CPB has been linked to postoperative neurologic deficits. The purpose of this study was to determine the accuracy of the coupled temperature measurement system and the CDI 500 arterial temperature sensor. Seventeen patients undergoing CPB were divided into four groups, each with a diffe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 44 2  شماره 

صفحات  -

تاریخ انتشار 2012