Relative dependence of diameters of branches in coronary bifurcations after stent implantation in main vessel--importance of carina position.

نویسندگان

  • Dobrin Vassilev
  • Robert J Gil
چکیده

BACKGROUND AND AIM Bifurcation lesions are relatively frequently encountered in everyday interventional practice. Stenting of the vessel chosen to be main (usually the larger one) frequently leads to stenosis at the ostium of the side branch (SB) and compromises its flow (side branch compromise--SBC). The relative dependence of main and side branch diameters, based on the concept of carina displacement of stent struts, was examined in a cohort of patients with bifurcation stenting. METHODS We accept that the basic mechanism for SBC after stent placement in the parent vessel is carina shifting from expanded stent struts. The ostial SB minimal lumen diameter (MLD), percentage diameter stenosis (%DS) at maximal and calculated actual carina displacement, as well as distal limb diameter (DLD) in the main branch were calculated and compared with actually observed values. RESULTS A group of 55 consecutive patients with acceptable quality angiograms formed the study population. General patient characteristics were similar to other bifurcation studies. Left anterior descending artery was predominantly treated in 73% of patients. There was worsening SB ostial stenosis after stent implantation (%DS increase from 48%+/-23% to 69%+/-21%, p <0.001) and final improvement because of kissing balloon inflation or SB postdilatation (post vs. final-69+/-21% and 53+/-25%, p<0.001). Stent implantation causes straightening of the main vessel, evident from a significant increase in angle C (pre- 148 degrees +/-19 degrees vs. 156 degrees +/-16 degrees after stenting, p=0.007). Relations between observed and predicted values for main branch DLD and %DS demonstrated a good correlation between predicted and observed values (for DLD r=0.66, p<0.001, and for %DS r=0.53, p <0.001). There was an excellent fit of regression lines between theoretical predictions and actual measurements for side branches (MLD r=0.91, p<0.001, %DS r=0.89, p<0.001). CONCLUSIONS Carina displacement from stent struts is a major mechanism governing changes in coronary bifurcations after main vessel stenting. Improvement in the ostium of the side branch causes shifting back of the carina and a decrease of main vessel diameter. The long-term consequences of this phenomenon are not currently known.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Do we know how to treat bifurcation coronary lesions?

Lesions located in an arterial bifurcation have traditionally been a challenge for percutaneous coronary intervention. At the time when balloon angioplasty was being used, these interventions were associated with increased risk of vascular occlusion, especially in the lateral branch, and also with a higher rate of restenosis. Suboptimal results in the main vessel, which sometimes had to be acce...

متن کامل

Application of 64-slice spiral computed tomography angiography in a follow-up evaluation after coronary stent implantation: A Chinese clinical study

Background: This study assessed the application value of 64-slice spiral computed tomography angiography (CTA) in a follow-up evaluation of patients receiving coronary stent implantation. Materials and Methods: A total of 468 patients who underwent percutaneous coronary intervention (PCI) at our hospital between January 2013 and October 2016 were selected for this study. Coronary angiography an...

متن کامل

عوامل پیشگویی‌کننده انسداد شاخه جانبی و عوارض زودرس آن به دنبال آنژیوپلاستی عروق کرونر

Background: Percutaneous Coronary Intervention (PCI) for bifurcated lesions is associated with a low rate of success and high rate of complications compared to such treatment of lesions of most other morphologies. Symptoms occurring at the time of procedure caused by PCI may require additional angiography with or without stenting through stent struts, which subsequently increases risks of reste...

متن کامل

Functional assessment of jailed side branches in coronary bifurcation lesions using fractional flow reserve.

OBJECTIVES This study was designed to assess the functional significance of side branches after stent implantation in main vessels using fractional flow reserve (FFR). BACKGROUND Little is known about the functional significance of side branches after stent implantation in main vessels in coronary bifurcation lesions. METHODS Between May 2007 and January 2011, 230 side branches in 230 patie...

متن کامل

Safety, Efficacy and Clinical Outcome of Direct Stent Implantation

Conventional methods of stenting require predilatation, which potentially increase vessel wall injury and cost of the procedure. In this study, the safety and efficacy of direct AVE-S7 (Medtronic-USA) stent placement were evaluated in 100 patients. Quantitative coronary angiography was performed at the baseline and post-stent. Clinical follow-up was done up to 9 months. In 100 patients (76 male...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Kardiologia polska

دوره 66 4  شماره 

صفحات  -

تاریخ انتشار 2008