Management of incision failure during small incision lenticule extraction because of conjunctivochalasis

نویسندگان

  • Bu Ki Kim
  • Su Joung Mun
  • Dae Gyu Lee
  • Hyun Tae Choi
  • Young Taek Chung
چکیده

Purpose We report a case of incision failure during small incision lenticule extraction (SMILE) and its management. Observations The incision could not be made using the femtosecond laser because of a redundant conjunctiva, so it was instead done manually using a diamond knife. The lenticule was successfully separated and extracted. Three months after the procedure, the uncorrected distance visual acuity was 20/20 and no complication was observed. Conclusions and importance This case demonstrates that the conjunctiva should be carefully examined before SMILE. If a complication occurs because of conjunctivochalasis, it can be resolved with proper management without compromising the patient's visual acuity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of femtosecond laser small-incision lenticule extraction and laser-assisted subepithelial keratectomy to correct myopic astigmatism.

PURPOSE To compare the efficacy of correcting myopic astigmatism with femtosecond laser small-incision lenticule extraction (SMILE, Carl Zeiss Meditec AG) versus laser-assisted subepithelial keratectomy (LASEK). SETTING The study was conducted at the Ophthalmology Department, Eye and ENT Hospital, Shanghai, China. DESIGN A retrospective, cross-sectional study. METHODS This study included ...

متن کامل

Efficacy, safety, predictability, contrast sensitivity, and aberrations after femtosecond laser lenticule extraction.

PURPOSE To compare femtosecond lenticule extraction and small-incision lenticule extraction to treat moderate to high myopia. SETTING Department of Ophthalmology, Aarhus University Hospital, Aarhus, Denmark. DESIGN Prospective clinical single-masked paired-eye study. METHODS An intrastromal lenticule was cut by a femtosecond laser and manually extracted. In femtosecond lenticule extractio...

متن کامل

Corneal biomechanical effects: small-incision lenticule extraction versus femtosecond laser-assisted laser in situ keratomileusis.

PURPOSE To compare the biomechanical properties of the cornea after small-incision lenticule extraction (lenticule extraction group) with those after femtosecond laser-assisted laser in situ keratomileusis (femtosecond LASIK group). SETTING Tianjin Eye Hospital & Eye Institute, Tianjin Key Laboratory of Ophthalmology and Visual Science, Tianjin Medical University, Tianjin, China. DESIGN Pro...

متن کامل

Safety and efficacy of VisuMax® circle patterns for flap creation and enhancement following small incision lenticule extraction

BACKGROUND The purpose of this case series is to evaluate the safety and efficacy of VisuMax® Circle patterns in eyes that have undergone small incision lenticule extraction, thus creating a flap to perform an enhancement procedure or residual lenticule extraction. METHODS This prospective, single center, case study series evaluated the use of a VisuMax® Circle pattern to create a corneal fla...

متن کامل

New Instruments for Lenticule Extraction in Small Incision Lenticule Extraction (SMILE)

Small incision lenticule extraction (SMILE) is an alternative to Laser-Assisted in situ Keratomileusis (LASIK) for correction of myopia. In cases where surgeons inadvertently dissect the posterior surface first, identification of the anterior surface and subsequent removal become difficult since the anterior surface of the lenticule is compacted against the anterior stromal surface. This may re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2017