Computed Tomography Iterative Reconstruction Techniques.

نویسنده

  • Benjamin Roberts
چکیده

For all their diagnostic value, computed tomography (CT) examinations have relatively high radiation exposure. Past efforts to decrease patient dose emphasized advances in data acquisition technology because attempts to decrease dose resulted in increased image noise from filtered back projection reconstruction techniques. Iterative reconstruction techniques lead to reduced dose and maintain image quality. Improvements in CT technology and protocols can enhance patient care, but the increased amount of data requires new methods for handling information. CT iterative reconstruction techniques present a powerful way to improve patient care and image quality.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast System Matrix Calculation in CT Iterative Reconstruction

Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...

متن کامل

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

Comparing IDREAM as an Iterative Reconstruction Algorithm against In Filtered Back Projection in Computed Tomography

Introduction: Recent studies of Computed Tomography (CT) conducted on patient dose reduction have recommended using an iterative reconstruction algorithm and mA (mili-Ampere) dose modulation. The current study aimed to evaluate Iterative Dose Reduction Algorithm (IDREAM) as an iterative reconstruction algorithm. Material and Methods: Two CT p...

متن کامل

Pii: S0895-6111(00)00060-4

Iterative reconstruction algorithms produce accurate images without streak artifacts as in ®ltered backprojection. They allow improved incorporation of important corrections for image degrading effects, such as attenuation, scatter and depth-dependent resolution. Only some corrections, which are important for accurate reconstruction in positron emission tomography and single photon emission com...

متن کامل

Visualization of simulated small vessels on computed tomography using a model-based iterative reconstruction technique

This article describes a quantitative evaluation of visualizing small vessels using several image reconstruction methods in computed tomography. Simulated vessels with diameters of 1-6 mm made by 3D printer was scanned using 320-row detector computed tomography (CT). Hybrid iterative reconstruction (hybrid IR) and model-based iterative reconstruction (MBIR) were performed for the image reconstr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiologic technology

دوره 87 6  شماره 

صفحات  -

تاریخ انتشار 2016