Origin and minimization of residual motion-related artifacts in navigator-corrected segmented diffusion-weighted EPI of the human brain.
نویسندگان
چکیده
Motion sensitivity in diffusion-weighted imaging (DWI) can be effectively suppressed using single-shot echo-planar imaging (EPI). However, segmented (multishot) EPI is often used to increase resolution and reduce spatial distortions, which in turn increases susceptibility to brain motion. The sources of these residual motion artifacts in navigator-echo-corrected segmented EPI images of the brain were investigated. The results indicate that the dominant source of these artifacts is cardiac pulsation with occasional involuntary movement of the subject. The relationship between the cardiac cycle and motion artifacts shows that optimum timing for the data acquisition is possible. In addition it is shown that the effects of involuntary motion can be removed by swapping k-space data between redundant datasets.
منابع مشابه
3D steady-state diffusion-weighted imaging with trajectory using radially batched internal navigator echoes (TURBINE).
While most diffusion-weighted imaging (DWI) is acquired using single-shot diffusion-weighted spin-echo echo-planar imaging, steady-state DWI is an alternative method with the potential to achieve higher-resolution images with less distortion. Steady-state DWI is, however, best suited to a segmented three-dimensional acquisition and thus requires three-dimensional navigation to fully correct for...
متن کاملCorrection for Involuntary Motion Related Artifacts in Multi-Shot EPI using k-space Data Swapping
Phase corrections based on readout-asymmetry and navigatorechoes can effectively reduce the motion-related phase errors in multi-shot EPI for diffusion weighted imaging studies. However, occasional involuntary motions might be too severe to be corrected by the navigator echoes. To minimize this effect, kspace data swapping technique is proposed in this study. By replacing the corrupted k-space ...
متن کاملDiffusion-Weighted, Readout-Segmented EPI with Synthesized T2- and T2*-Weighted Images
Purpose: Diffusion-weighted Imaging (DWI) using readout-segmented EPI (rs-EPI) with 2D navigator correction [1] is an alternative to standard single-shot EPI (ss-EPI) that improves image quality by reducing susceptibility artifacts and allowing a higher spatial resolution. This improved image quality raises the possibility that the low b-value image could be used to replace a separate T2-weight...
متن کاملHigh-resolution diffusion weighted MRI enabled by multi-shot EPI with multiplexed sensitivity-encoding
Nan-kuei Chen, Arnaud Guidon, Hing-Chiu Chang, and Allen W Song Brain Imaging and Analysis Center, Duke University, Durham, NC, United States Target audience: Neuroimaging researchers and clinicians who are interested in high-resolution diffusion-weighted imaging Purpose: The goal of this study is to develop a novel post-processing algorithm, enabling diffusion weighted imaging (DWI) of high-qu...
متن کاملPhysiological motion artifact correction in segmented DTI measurement of anesthetized non-human primates
Introduction. Diffusion tensor imaging (DTI) is widely used to study white matter diseases and map fiber tracts in vivo [1]. However DTI is susceptible to any motion during scanning. Segmented EPI, which is often used to achieve higher spatial resolution tensor images for anesthetized non-human primate subjects, is especially vulnerable to inherent physiological motion. Motion results in corrup...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medicine
دوره 47 4 شماره
صفحات -
تاریخ انتشار 2002