New Technique for Dorsal Fragment Reduction in Distal Radius Fractures by Using Volar Bone Fenestration
نویسندگان
چکیده
INTRODUCTION For intra-articular distal radius fractures (AO Classification, type B2) with a displaced dorsal fragment, there remains much discussion on the fixation method for the dorsal fragment. To reduce the displaced dorsal fragment, we developed a new technique consisting of fenestration of the volar bone cortex, reduction using an intramedullary procedure, and fixation using a volar plate. This avoids necessity of dorsal approach. TECHNICAL NOTE We performed this surgical technique in 2 patients and achieved a good reduced position without much injury to the bone cortex at the site of volar plate placement. This surgical technique allows reduction of the dorsal fragment using an intramedullary procedure by only a volar approach, and, therefore, does not affect the dorsal soft tissue (extensor tendon). For intra-articular distal radius fractures, complete reduction of the articular surface is extremely difficult, and, in patients with a remaining gap on the articular surface, a variable angle locking screw system may be useful. In the 2 patients, the angle of the locking screw was adjusted to catch the displaced dorsal fragment, and adequate reduction and fixation could be achieved. CONCLUSION This technique using fenestration of the volar bone cortex allows reduction and fixation of the displaced dorsal fragment in distal radius fractures and thus avoids the necessity of a dorsal approach.
منابع مشابه
Short-term Results of Using Injectable Bone Cement Technique in the Treatment of Unstable Distal Radius Fractures
Background & Aims: Treatment of osteoporotic distal radius fracture with metaphyseal defect is often complicated by secondary displacement, because of posterior cortex comminution. The aim of this study was to investigate functional outcomes and advantages of injection of bone cement in stabilizing and maintaining this fracture reduction. Methods: This prospective study was performed on 20 ...
متن کاملDevising for a distal radius fracture fixation focus on the intra-articular volar dislocated fragment
INTRODUCTION Distal radius fracture (DRF) accompanied by intra-articular volar displaced fragment is difficult to reduce. This volar fragment remains when treated with a simple buttress effect alone, and V-shaped deformity may remain on the articular surface. We attempted to improve dorsal rotational deviation of volar fragment by osteosynthesis applying the condylar stabilizing technique. We r...
متن کاملThe extended flexor carpi radialis approach: a new perspective for the distal radius fracture.
Volar fixation of dorsally unstable distal radius fractures is a new method of treatment that provides the benefits of stable internal fixation without the complications of the dorsal approach. A new, fixed-angle fixation device, the distal volar radius (DVR) plate, (Fig. 1) has been introduced for this purpose. Experience gained by applying this technique to clinically complex cases led us to ...
متن کاملVolar fixed-angle fixation of distal radius fractures: the DVR plate.
Volar fixed-angle fixation of distal radius fractures is a new method of treatment that provides the benefits of stable internal fixation without incurring the disadvantages of the dorsal approach. The DVR plate is a new fixation implant that was introduced specifically for the purpose of managing both dorsal and volar displaced fractures from the volar aspect. Experience gained applying volar ...
متن کاملComplications of volar plating of distal radius fractures.
Open reduction and internal fixation has been shown to be effective in the treatment of unstable distal radius fractures. When a dorsal approach is used, extensor tendons rupture or irritation are frequent and well known complications. Complications associated with volar plate fixation have not been studied to the same extent. In this study a homogenous series of 90 patients treated by volar pl...
متن کامل