Mechanical characteristics of counterfeit Reciproc instruments: a call for attention.

نویسندگان

  • C S Rodrigues
  • V T L Vieira
  • H S Antunes
  • G De-Deus
  • C N Elias
  • E J L Moreira
  • E J N L Silva
چکیده

AIM To report the main differences seen by direct visual inspection between original and counterfeit Reciproc instruments, together with an evaluation of instrument bending resistance, cyclic fatigue, surface finish, Vickers microhardness and chemical composition. METHODOLOGY The visual aspects of original Reciproc R25 (VDW, Munich, Germany) and counterfeit Reciproc R25 instruments (claimed to be original, supposedly with dimensions similar to those of Reciproc R25 files, bought at www.mercadolivre.com.br) were evaluated under direct observation, stereomicroscopy and scanning electron microscope. The flexibility of original and counterfeit Reciproc R25 was determined via 45° bending tests according to the ISO 3630-1 specification. Instruments were also subjected to cyclic fatigue resistance, measuring the time to fracture in an artificial stainless steel canal with a 60° angle and 5-mm radius of curvature. The fracture surfaces of all fragments were examined under a scanning electron microscope. Roughness of the instruments was quantified using a profilometer, and the microhardness test was carried out using a Vickers hardness tester. Energy-dispersive X-ray microanalysis (EDX) was also carried out. Results were analysed statistically using the Student's t-test at a significance level of P < 0.05. RESULTS Although the packaging of the original and counterfeit instruments was similar, a number of differences were observed such as ISO colour coding, measurement marks, stopper and morphologic characteristics. Original Reciproc instruments had significantly longer cyclic fatigue life and significantly lower bending resistance than counterfeit Reciproc instruments (P < 0.05), as well as significantly lower microhardness and roughness (P < 0.05). EDX results revealed differences in the chemical composition of the instruments (P < 0.05), indicating that the instruments were manufactured with different raw material. CONCLUSION Original Reciproc files outperformed counterfeit instruments in all tests. It is thus important that identification strategies for these counterfeit instruments be developed, thereby preventing their inadvertent use.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new device to test cutting efficiency of mechanical endodontic instruments

BACKGROUND The purpose of the present study was to introduce a new device specifically designed to evaluate the cutting efficiency of mechanically driven endodontic instruments. MATERIAL AND METHODS Twenty new Reciproc R25 (VDW, Munich, Germany) files were used to be investigated in the new device developed to test the cutting ability of endodontic instruments. The device consists of a main f...

متن کامل

Cyclic fatigue of Reciproc and WaveOne reciprocating instruments.

AIM To evaluate the cyclic fatigue resistance of Reciproc(®) and WaveOne(®) instruments in simulated root canals. METHODOLOGY Two groups of 15 NiTi endodontic instruments of identical tip size of 0.25 mm were tested, group A; Reciproc(®) R25 and group B: WaveOne(®) primary. Cyclic fatigue testing was performed in a stainless steel artificial canal manufactured by reproducing the instrument's ...

متن کامل

Safe Mechanical Preparation with Reciprocation Movement without Glide Path Creation: Result from a Pool of 673 Root Canals.

The aim of the present study was to prospectively assess the frequency of teeth in which the Reciproc instruments were able to reach the full working length (WL). This case series study enrolled 277 consecutive teeth requiring primary endodontic treatment performed with the Reciproc system (VDW) without a previous glide path by 3 experienced endodontists. Instruments R25, R40 or R50 were select...

متن کامل

A comparison of two reciprocating instruments using bending stress and cyclic fatigue tests.

The aim of this study was to comparatively evaluate the bending resistance at 45º, the static and dynamic cyclic fatigue life, and the fracture type of the WaveOne (Dentsply Maillefer, Ballaigues, Switzerland) 25-08 and Reciproc (VDW, Munich, Germany) 25-08 instruments. A total of 60 nickel-titanium (NiTi) instruments (30 Reciproc and 30 WaveOne) from three different lots, each of which was 25 ...

متن کامل

Cutting efficiency of Reciproc and waveOne reciprocating instruments.

INTRODUCTION The aim of the present study was to evaluate the cutting efficiency of 2 new reciprocating instruments, Reciproc and WaveOne. METHODS Twenty-four new Reciproc R25 and 24 new WaveOne Primary files were activated by using a torque-controlled motor (Silver Reciproc) and divided into 4 groups (n = 12): group 1, Reciproc activated by Reciproc ALL program; group 2, Reciproc activated b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International endodontic journal

دوره   شماره 

صفحات  -

تاریخ انتشار 2017