In situ study of the impact of inter- and intra-reader variability on region of interest (ROI) analysis in preclinical molecular imaging.

نویسندگان

  • Frezghi Habte
  • Shradha Budhiraja
  • Shay Keren
  • Timothy C Doyle
  • Craig S Levin
  • David S Paik
چکیده

We estimated reader-dependent variability of region of interest (ROI) analysis and evaluated its impact on preclinical quantitative molecular imaging. To estimate reader variability, we used five independent image datasets acquired each using microPET and multispectral fluorescence imaging (MSFI). We also selected ten experienced researchers who utilize molecular imaging in the same environment that they typically perform their own studies. Nine investigators blinded to the data type completed the ROI analysis by drawing ROIs manually that delineate the tumor regions to the best of their knowledge and repeated the measurements three times, non-consecutively. Extracted mean intensities of voxels within each ROI are used to compute the coefficient of variation (CV) and characterize the inter- and intra-reader variability. The impact of variability was assessed through random samples iterated from normal distributions for control and experimental groups on hypothesis testing and computing statistical power by varying subject size, measured difference between groups and CV. The results indicate that inter-reader variability was 22.5% for microPET and 72.2% for MSFI. Additionally, mean intra-reader variability was 10.1% for microPET and 26.4% for MSFI. Repeated statistical testing showed that a total variability of CV < 50% may be needed to detect differences < 50% between experimental and control groups when six subjects (n = 6) or more are used and statistical power is adequate (80%). Surprisingly high variability has been observed mainly due to differences in the ROI placement and geometry drawn between readers, which may adversely affect statistical power and erroneously lead to negative study outcomes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of region of interest size and location in Gafchromic film dosimetry

Introduction: Accurate film dosimetry requires careful consideration of sources of uncertainty. Some of the sources of uncertainty are dependent on the size and location of region of interest (ROI), especially in small fields. Avoiding the penumbra is often a reason for using a small ROI. In contrast, choosing very small ROIs may increase uncertainty due to the reduction of th...

متن کامل

Impact of region-of-interest method on quantitative analysis of DTI data in the optic tracts

BACKGROUND To extract DTI parameters from a specific structure, a region of interest (ROI) must be defined. ROI selection in small structures is challenging; the final measurement results could be affected due to the significant impact of small geometrical errors. In this study the optic tracts were analyzed with the aim to assess differences in DTI parameters due to ROI method and to identify ...

متن کامل

Towards standardization of 18F-FET PET imaging: do we need a consistent method of background activity assessment?

BACKGROUND PET with O-(2-18F-fluoroethyl)-L-tyrosine (18F-FET) has reached increasing clinical significance for patients with brain neoplasms. For quantification of standard PET-derived parameters such as the tumor-to-background ratio, the background activity is assessed using a region of interest (ROI) or volume of interest (VOI) in unaffected brain tissue. However, there is no standardized ap...

متن کامل

Quantification of partial volume effects in planar imaging

Introduction: The limited resolution of the imaging system causes partial volume effects (PVEs). These results in spreading of image counts to the neighboring pixels. This phenomenon is called spill-out effect. This study aimed at quantifying PVEs using ImageJ. Methods:Technetium-99m solution of concentration of 74 kBq/ml was filled into spheres A, B<...

متن کامل

Validation of Optimum ROI Size for 123I-FP-CIT SPECT Imaging Using a 3D Mathematical Cylinder Phantom

Objective(s): The partial volume effect (PVE) of single-photon emission computed tomography (SPECT) on corpus striatum imaging is caused by the underestimation of specific binding ratio (SBR). A large ROI (region of interest) set using the Southampton method is independent of PVE for SBR. The present study aimed to determine the optimal ROI size with contrast and SBR for striatum images and val...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • American journal of nuclear medicine and molecular imaging

دوره 3 2  شماره 

صفحات  -

تاریخ انتشار 2013