Valved Glaucoma Drainage Devices in Pediatric Glaucoma: Retrospective Long-term Outcomes.

نویسندگان

  • Andrew Chen
  • Fei Yu
  • Simon K Law
  • JoAnn A Giaconi
  • Anne L Coleman
  • Joseph Caprioli
چکیده

IMPORTANCE Relatively little data exist about the long-term outcomes of an initial glaucoma drainage device (GDD) and subsequent GDDs implanted in pediatric patients with glaucoma. OBJECTIVE To determine the long-term outcomes of the first and second GDDs and risk factors in pediatric glaucoma. DESIGN, SETTING, AND PARTICIPANTS Retrospective review of 119 eyes of 89 patients younger than 18 years with glaucoma who underwent valved GDD implantation from March 1999 to April 2012 at the Stein Eye Institute, University of California, Los Angeles. EXPOSURE Implantation of GDD, using silicone and polypropylene Ahmed glaucoma valve. MAIN OUTCOMES AND MEASURES Kaplan-Meier survival analysis and risk factors associated with GDD failure. Success was defined as a final intraocular pressure of 5 to 21 mm Hg as well as a 20% reduction from baseline intraocular pressure with or without medications. RESULTS The mean (SD) age at implantation of the first GDD was 6.8 (5.7) years. The mean (SD) follow-up time was 6.1 (3.3) years from surgery. The mean intraocular pressure was reduced by 13.0 mm Hg (95% CI, 8.8 to 17.3 mm Hg) at 5 years postoperatively. The mean number of glaucoma medications preoperatively vs postoperatively was not different starting at 5 years (reduction of 0.5; 95% CI, -0.1 to 1.0). The success rate at 5 years was 55.0% (95% CI, 46.0% to 65.9%). Risk factor analysis suggests that older age (risk ratio = 0.95; 95% CI, 0.90 to 0.99; P = .02), uveitic glaucoma (risk ratio = 0.34; 95% CI, 0.14 to 0.86; P = .02), and polypropylene GDDs (risk ratio = 0.39; 95% CI, 0.23 to 0.67; P = .001) were associated with higher success rates. Thirty-six eyes received a second GDD, with a mean (SD) of 2.2 (1.6) years between the 2 operations. The success rate 5 years after the second surgery was 52.8% (95% CI, 37.0% to 75.3%). Risk factors associated with failure of the first GDD were not found to affect the likelihood of failure for the second. CONCLUSIONS AND RELEVANCE Glaucoma drainage devices, such as the Ahmed glaucoma valve, have moderate long-term success rates in pediatric patients with glaucoma. In pediatric patients, the first GDD is successful in 46% to 70% of patients at 5 years with medications, and the second GDD is successful in 37% to 75% of patients at 5 years after the subsequent surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Artificial drainage devices for glaucoma surgery: an overview.

Artificial drainage devices (ADD) create an alternative pathway for aqueous drainage from the anterior chamber of an eye through a tube to the subconjunctival bleb connected to an equatorial plate under the conjunctiva. The ADDs, both valved and non-valved, are available for end stage or refractory glaucoma. Currently, some of these devices, particularly the Express shunt, are recommended for t...

متن کامل

Glaucoma drainage implants: a critical comparison of types.

PURPOSE OF REVIEW The purpose of this review is to critically compare the various glaucoma drainage implants in popular use. RECENT FINDINGS Glaucoma drainage implants are being increasingly utilized in the surgical management of glaucoma. Comparisons between the various drainage implants are difficult because most clinical data are derived from retrospective studies with different study popu...

متن کامل

Using Ahmed’s Gonioimplant Valve to Surgical Treatment of Glaucoma in Two Dogs

Case Description- An eleven-year-old Golden retriever male dog (dog I) and a four-year-old neutered Toy Terrier (dog II) were referred to Small Animal Clinic. Dog I was suffered from   partial loss of vision and engorgement of episcleral vessels of his right eye and dog II was blind. Intraocular pressure (IOP) of right eye was 37.8 mmHg in dog  I  and 34.5 and 31.6 mmHg in the right and left...

متن کامل

Glaucoma Surgery in Pregnancy: A Case Series and Literature Review

AbstractGlaucoma management in pregnant patients is a real challenge, especially when the glaucoma is not controlled with medications. We report the results of 6 incisional glaucoma surgeries for the management of medically uncontrolled glaucoma patients during pregnancy. This retrospective, case series was conducted on the 6 eyes of 3pregnant patients with uncontrolled glaucoma using maximum t...

متن کامل

Intraocular and extraocular hemorrhage associated with ligature release of non-valved glaucoma drainage implant

Purpose To report a rare complication of non-valved glaucoma drainage device surgery. Observations An 85-year-old pseudophakic white male presented with painless vision loss and bloody tears. He was 5 weeks removed from uncomplicated non-valved glaucoma drainage device (Baerveldt 101-350, [AMO, Santa Clara, CA]). There was serosanguinous discharge without apparent source and a 25% layering hy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JAMA ophthalmology

دوره 133 9  شماره 

صفحات  -

تاریخ انتشار 2015