Is the Comet Assay a Sensitive Procedure for Detecting Genotoxicity?
نویسندگان
چکیده
Although the Comet assay, a procedure for quantitating DNA damage in mammalian cells, is considered sensitive, it has never been ascertained that its sensitivity is higher than the sensitivity of other genotoxicity assays in mammalian cells. To determine whether the power of the Comet assay to detect a low level of genotoxic potential is superior to those of other genotoxicity assays in mammalian cells, we compared the results of Comet assay with those of micronucleus test (MN test). WTK1 human lymphoblastoid cells were exposed to methyl nitrosourea (MNU), ethyl nitrosourea (ENU), methyl methanesulfonate (MMS), ethyl methanesulfonate (EMS), bleomycin (BLM), or UVC. In Comet assay, cells were exposed to each mutagen with (Comet assay/araC) and without (Comet assay) DNA repair inhibitors (araC and hydroxyurea). Furthermore, acellular Comet assay (acellular assay) was performed to determine how single-strand breaks (SSBs) as the initial damage contributes to DNA migration and/or to micronucleus formation. The lowest genotoxic dose (LGD), which is defined as the lowest dose at which each mutagen causes a positive response on each genotoxicity assay, was used to compare the power of the Comet assay to detect a low level of genotoxic potential and that of MN test; that is, a low LGD indicates a high power. Results are summarized as follows: (1) for all mutagens studied, LGDs were MN test ≦ Comet assay; (2) except for BLM, LGDs were Comet assay/araC ≦ MN test; (3) except for UVC and MNU, LGDs were acellular assay ≦ Comet assay/araC ≦ MN test ≦ Comet assay. The following is suggested by the present findings: (1) LGD in the Comet assay is higher than that in MN test, which suggests that the power of the MN test to detect a low level of genotoxic potential is superior to that of the Comet assay; (2) for the studied mutagens, all assays were able to detect all mutagens correctly, which suggests that the sensitivity of the Comet assay and that of the MN test were exactly identical; (3) the power of the Comet assay to detect a low level of genotoxic potential can be elevated to a level higher than that of MN test by using DNA resynthesis inhibitors, such as araC and HU.
منابع مشابه
Comet assay as a sensitive technique in occupational health studies; A literature review
Background: Occupational health is a sensitive field in many countries where occupational exposure needs attention due to the lack of awareness. Several businesses, including leather, textile, iron, steel, and dyeing industries use a variety of mutagenic and genotoxic chemicals. Exposure to these chemicals may pose serious health risks, including genetic damage to workers. Comet assay is a tech...
متن کاملThe Power of the Comet Assay to Detect Low Level Genotoxicity and DNA Repair Factors Affecting its Power
The comet assay is considered to be a rapid and sensitive procedure for quantitating DNA damage in mammalian cells. In this article, to interpret its outcomes adequately, its power to detect low level genotoxicity and factors affecting its power were reviewed. Although the development of initial lesions into alkali-labile sites and/or SSBs through repairing events is an important factor to supp...
متن کاملCytogenetic damage induced by crude oil in Anodonta cygnea (mollusca,bivalvia) assessed by the comet assay and micronucleus test
Crude oil is enriched in polycyclic aromatic hydrocarbons (PAHs). Many PAH analogs have proved to potentially damage DNA. DNA damage can be assessed using various biomarkers to find out the degree of genotoxicity of pollutants following in vitro exposure. In this research the comet assay and micronucleus (MN) test were used to detect DNA damages and cytogenetic changes following crude oil expos...
متن کاملComet assay: a method to evaluate genotoxicity of nano-drug delivery system.
INTRODUCTION Drug delivery systems could induce cellular toxicity as side effect of nanomaterials. The mechanism of toxicity usually involves DNA damage. The comet assay or single cell gel electrophoresis (SCGE) is a sensitive method for detecting strand damages in the DNA of a cell with applications in genotoxicity testing and molecular epidemiology as well as fundamental research in DNA damag...
متن کاملCytotoxicity and Genotoxicity Evaluation of Fluorapatite/bioactive Glass Nanocomposite Foams With Two Various Weight Ratios as Bone Tissue Scaffold: an in vitro study
The optimization of biomaterials’ biodegradation rate similar to tissue regeneration, is one of the main goals of tissue engineering. However, the necessity to assess their possible toxicity is always considered. The aim of this study was cytotoxicity and genotoxicity evaluation of fluorapatite/bioactive glass (FA/BG) nanocomposite foams with two various weight ratios to determine the optimal c...