Substantial discrepancies in 17beta-oestradiol concentrations obtained with three different commercial direct radioimmunoassay kits in rat sera.
نویسندگان
چکیده
The extensive use of oestrogen for contraception and amelioration of post-menopausal symptoms has made it the subject of substantial recent research efforts, and ovariectomized (ovx) rats treated with exogenous ovarial hormones are important when investigating the effects and mechanisms of oestrogen actions. The crucial need to control and monitor plasma levels of 17beta-oestradiol calls for accurate, precise and robust assay methods. The performance of direct radioimmunoassays (RIAs) in measurement of 17beta-oestradiol has been reported previously for human samples, but to our knowledge not for rat samples. In the current study, 552 serum samples from ovx, native and hormone-treated rats were used to compare the performance of three commercially manufactured direct RIAs from the companies DPC (Siemens Healthcare Diagnostics Inc., formerly Diagnostic Products Corporation), DSL (Diagnostic Systems Labs) and MPB (MP Biomedicals, formerly ICN Biomedicals). Substantial differences in results between the three assay methods were found when measuring serum 17beta-oestradiol concentrations. The following formulas describing the relation between the different methods were obtained using weighted Deming's orthogonal regression (based on pg/mL): DSL = 0.43*DPC+12.3, MPB = 2.1*DPC+84.7 and DSL = 4.8*MPB+22.2. Furthermore, a preceding diethyl ether extraction step of the serum appears to impair the performance of the RIAs in the present samples (based on pg/mL): DPC(ex) = 0.39*DPC(unex)+0.76, DSL(ex) = 0.32*DSL(unex)-1.7 and MPB(ex) = 0.22*MPB(unex)+1.4.
منابع مشابه
Order of magnitude differences between methods for maintaining physiological 17beta-oestradiol concentrations in ovariectomized rats.
The use of animal models, especially the rat, is crucial for elucidating the biological effects and mechanisms of the widely used hormone 17beta-oestradiol. Unfortunately, there is a lack of consensus on optimal means of obtaining and maintaining physiological 17beta-oestradiol concentrations in plasma and this may be the reason for the varying results in several studies, including the disagree...
متن کاملA purification step prior to commercial sensitive immunoassay is necessary to achieve clinical usefulness when quantifying serum 17beta-estradiol in prepubertal children.
OBJECTIVE To test the clinical usefulness of sensitive commercial immunoassays for determination of low 17beta-estradiol concentrations in children. METHODS The lower limit of detection and clinical usefulness (functional sensitivity) of three commercial estradiol immunoassays were validated by use of 500 sera from prepubertal and pubertal children and 55 pooled sera. The three immunoassays c...
متن کاملComparative analysis of different commercial ELISA systems for the detection of anti-neutrophil cytoplasm antibodies in ANCA-associated vasculitides.
OBJECTIVES To assess the diagnostic performance of 11 commercial PR3- and MPO-ANCA ELISA systems (direct, capture and high sensitive [hs] ELISA). METHODS Sera from 90 patients with AAV (GPA, MPA and CSS) and 20 disease controls (SLE; RA) and healthy individuals were tested for the presence of ANCA by IFT and by different ELISAs for the presence of PR3-and MPO-ANCA, respectively. Furthermore, ...
متن کاملComparison of commercial kits for radioimmunoassay: III. Radioassay of serum folate.
We evaluated six commercial radioassay kits in which tritium or iodine tracers are used to measure serum folate. We assessed the adequacy of the literature supplied with the kits, within-run precision, reagent stability, analytical recovery of added pteroylglutamic acid and N-methyltetrahydrofolic acid, results of analysis of patients' samples, and minimum detection limits. There were serious d...
متن کاملTen commercial kits compared for assay of thyrotropin in the normal and thyrotoxic range.
I developed a standard procedure for assessing sensitivity, intra-assay precision, parallelism of sample dilutions, and assay drift, using a single trial assay kit. I used this to compare the performance of 10 commercial kits with an in-house radioimmunoassay for human thyrotropin. No one kit stood out as clearly superior overall. Differences in calibration between kits were evident in a compar...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Scandinavian journal of clinical and laboratory investigation
دوره 68 8 شماره
صفحات -
تاریخ انتشار 2008