Chemically blocked analog assays for free thyronines. I. The effect of chemical blockers on T4 analog and T4 binding by albumin and by thyroxin-binding globulin.
نویسندگان
چکیده
Analog assays for free thyroxin (FT4) produce inaccurate results because the T4 analog is sequestered by albumin. Diagnostic Products Corp. (DPC) introduced the concept of chemically blocking analog-albumin binding in 1982. While DPC succeeded in eliminating albumin dependence, their 1985 version of chemically blocked FT4 assay appeared to be "thyroxin-binding globulin" (TBG) dependent, producing inappropriately low FT4 results with low TBG concentrations and high results with high TBG concentrations. We examined the effects of chemical blockers on albumin and TBG binding, using equilibrium dialysis to measure free fractions of T4 analog and T4. We then created FT4 assays in which various concentrations of chemical blockers were used to demonstrate their effects on FT4 estimates in patients with low or increased TBG concentrations or who were pregnant. We found that chemical blockers do displace T4 analog from albumin, but also displace T4 from albumin and, in high concentrations, from TBG as well. It is this displacement of T4 from TBG by chemical blockers that resulted in "TBG dependence" of DPC FT4 estimates. This problem has been corrected in currently available versions of the DPC FT4 kit.
منابع مشابه
Chemically blocked analog assays for free thyronines. II. Use of equilibrium dialysis to optimize the displacement by chemical blockers of T4 analog and T3 analog from albumin while avoiding displacement of T4 and T3 from thyroxin-binding globulin.
Chemical blockers used to displace thyronine analog from albumin in analog kits for assay of free thyroxin (FT4) or free triiodothyronine (FT3) may also displace thyroxin (T4) or triiodothyronine (T3) from thyroxin-binding globulin (TBG), resulting in an apparent TBG dependence of results of free hormone estimates. We used equilibrium dialysis and antibody binding to assess the displacement of ...
متن کامل"Unbound analog" radioimmunoassays for free thyroxin measure the albumin-bound hormone fraction.
We have assessed the influence of albumin-bound thyroxin (T4) on apparent free T4 values obtained by two "unbound analog" free T4 methods (AmerlexR Free T4 and Clinical Assays one-step Free T4). We evaluated sera showing three different albumin anomalies: total hereditary analbuminemia, partially corrected analbuminemia, and familial dysalbuminemic hyperthyroxinemia, where abnormal albumin-bind...
متن کاملDirect and indirect techniques for free thyroxin compared in patients with nonthyroidal illness. II. Effect of prealbumin, albumin, and thyroxin-binding globulin.
We studied the correlation of thyroxin (T4)-binding proteins with the apparent free T4 (FT4) in 101 patients with nonthyroidal illness (NTI). Most patients (95%) were seriously ill at the time of blood collection. Concentrations of T4-binding prealbumin (transthyretin), albumin, and T4-binding globulin (TBG) often were low in the sera of these patients. Albumin was the most frequently subnormal...
متن کاملEffect of albumin concentration on the assay of serum free thyroxin by equilibrium radioimmunoassay with labeled thyroxin analog (Amerlex Free T4).
Serum free thyroxin (FT4) in normal nonpregnant and pregnant subjects was measured by radioimmunoassay (RIA) with Amerlex FT4 RIA (Amersham International) and LiquiSol FT4 RIA (Damon Diagnostics) kits. Amerlex FT4 values in serum from pregnant women were lower than those in serum from nonpregnant women, but LiquiSol FT4 values were similar in serum from both groups. Amerlex FT4 values were dire...
متن کاملAn evaluation of a fluorescence polarization immunoassay of thyroxin and thyroxin-uptake.
We evaluated the fluorescence polarization immunoassay for total thyroxin (T4) and thyroxin-uptake (T-U) in the Abbott "TDx" Analyzer. Between-assay precision was good when we did once-fortnightly calibration and assayed samples in singleton. Measured T4 concentration was decreased in hemolyzed samples with obvious red coloration and undetectable in severely hemolyzed samples. The T-U assay was...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 34 1 شماره
صفحات -
تاریخ انتشار 1988