Validation of shear wave elastography in skeletal muscle.
نویسندگان
چکیده
Skeletal muscle is a very dynamic tissue, thus accurate quantification of skeletal muscle stiffness throughout its functional range is crucial to improve the physical functioning and independence following pathology. Shear wave elastography (SWE) is an ultrasound-based technique that characterizes tissue mechanical properties based on the propagation of remotely induced shear waves. The objective of this study is to validate SWE throughout the functional range of motion of skeletal muscle for three ultrasound transducer orientations. We hypothesized that combining traditional materials testing (MTS) techniques with SWE measurements will show increased stiffness measures with increasing tensile load, and will correlate well with each other for trials in which the transducer is parallel to underlying muscle fibers. To evaluate this hypothesis, we monitored the deformation throughout tensile loading of four porcine brachialis whole-muscle tissue specimens, while simultaneously making SWE measurements of the same specimen. We used regression to examine the correlation between Young's modulus from MTS and shear modulus from SWE for each of the transducer orientations. We applied a generalized linear model to account for repeated testing. Model parameters were estimated via generalized estimating equations. The regression coefficient was 0.1944, with a 95% confidence interval of (0.1463-0.2425) for parallel transducer trials. Shear waves did not propagate well for both the 45° and perpendicular transducer orientations. Both parallel SWE and MTS showed increased stiffness with increasing tensile load. This study provides the necessary first step for additional studies that can evaluate the distribution of stiffness throughout muscle.
منابع مشابه
Shear wave group velocity inversion in MR elastography of human skeletal muscle.
In vivo quantification of the anisotropic shear elasticity of soft tissue is an appealing objective of elastography techniques because elastic anisotropy can potentially provide specific information about structural alterations in diseased tissue. Here a method is introduced and applied to MR elastography (MRE) of skeletal muscle. With this method one can elucidate anisotropy by means of two sh...
متن کاملThe measurement of anisotropic elasticity in skeletal muscle using MR Elastography
T. Oida, Y. Kang, T. Azuma, J. Okamoto, A. Amano, L. Axel, O. Takizawa, S. Tsutsumi, T. Matsuda Graduate School of Informatics, Kyoto University, Kyoto, Kyoto, Japan, Institute for Frontier Medical Sciences, Kyoto University, Kyoto, Kyoto, Japan, Siem ens-Asahi Medical Technologies Ltd., Shinagawa-ku, Tokyo, Japan, Department of Radiology, New York University School of Medicine, New York, New Y...
متن کاملMeasuring the effects of acupuncture on muscle stiffness with shear wave elastography.
Acupunct Med Month 2017 Vol 0 No 0 Figure 1 Shear wave elastography of the gastrocnemius muscle in a longitudinal plane. Rectangular field of view demonstrating good quality shear-wave elastogram as indicated by homogeneously distributed blue colour-coded muscle (A) and evenly spaced propagation waves (B). Quantitative analysis of gastrocnemius muscle stiffness was achieved by placing the small...
متن کاملElucidation of Isotropic and Anisotropic Shear Elasticity of in vivo Soft Tissue using Planar Magnetic Resonance
Magnetic resonance elastography (MRE) is a noninvasive method that allows the determination of in vivo shear elasticity of soft tissues. In this thesis methods for the determination of isotropic and anisotropic shear elasticities from MRE wave data were developed and evaluated. All methods presented in this work are based on planar MRE, i.e. they are based on the measurement of a single displac...
متن کاملValidity of Measurement of Shear Modulus by Ultrasound Shear Wave Elastography in Human Pennate Muscle
Ultrasound shear wave elastography is becoming a valuable tool for measuring mechanical properties of individual muscles. Since ultrasound shear wave elastography measures shear modulus along the principal axis of the probe (i.e., along the transverse axis of the imaging plane), the measured shear modulus most accurately represents the mechanical property of the muscle along the fascicle direct...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomechanics
دوره 46 14 شماره
صفحات -
تاریخ انتشار 2013