Operative Management of Sciatic Nerve Palsy due to Impingement on the Metal Cage after Total Hip Revision: Case Report
نویسندگان
چکیده
This paper discusses a sciatic nerve palsy developed after a right total hip revision with a Burch-Schneider metal cage. A sciatalgic nerve pain appeared after surgery, while the palsy developed in about fifteen days. An electromyography showed the delay of the nerve impulse gluteal level. During the surgical exploration of the hip, a compression of the nerve on the metal cage was observed. The nerve was isolated, released from the fibrotic tissue and from the impingement, and was protected with a muscular flap. The recover from the pain was immediate, while the palsy recovered one month later.
منابع مشابه
Early results of trabecular metal augment for acetabular reconstruction in revision hip arthroplasty.
The management of acetabular bone defects presents a challenge in revision total hip arthroplasty (THA). The aim of this study was to assess the early clinical and radiological outcome of revision of acetabular components using trabecular metal cups and augments for acetabular reconstruction. The study included 18 consecutive patients with failed acetabular components after total hip arthroplas...
متن کاملDelayed Presentation of Sciatic Nerve Injury after Total Hip Arthroplasty: Neurosurgical Considerations, Diagnosis, and Management
BACKGROUND Total hip arthroplasty (THA) is an established treatment for end-stage arthritis, congenital deformity, and trauma with good long-term clinical and functional outcomes. Delayed sciatic nerve injury is a rare complication after THA that requires prompt diagnosis and management. METHODS We present a case of sciatic nerve motor and sensory deficit in a 52-year-old patient 2 years afte...
متن کاملSciatic nerve palsy after total hip replacement.
We report a case of sciatic nerve palsy following total hip replacement which has lead to a novel hypothesis to account for this complication.
متن کاملSciatic Nerve Palsy Caused by Ruptured and Contracted Short External Rotator Muscles after Primary Total Hip Arthroplasty
Although the incidence of sciatic nerve palsy following total hip arthroplasty is low, this complication can cause devastating permanent nerve palsy. The authors experienced a case of sciatic nerve palsy caused by ruptured and contracted external rotator muscles following total hip arthroplasty in a patient suffering from osteonecrosis of the femoral head. We report this unusual case of sciatic...
متن کاملTreatment of postoperative sciatic nerve palsy after total hip arthroplasty for postoperative acetabular fracture: A case report
Acetabular fracture is usually treated with osteosynthesis. However, in the case of an intra-articular fracture, osteosynthesis can result in arthropathy of the hip joint and poor long-term results, hence, total hip arthroplasty is required. However, in total hip arthroplasty for postoperative acetabular fracture, sciatic nerve palsy tends to develop more commonly than after primary total hip a...