Signal reconstruction of the slow wave and spike potential from electrogastrogram.

نویسندگان

  • Shujia Qin
  • Wei Ding
  • Lei Miao
  • Ning Xi
  • Hongyi Li
  • Chunmin Yang
چکیده

The gastric slow wave and the spike potential can correspondingly represent the rhythm and the intensity of stomach motility. Because of the filtering effect of biological tissue, electrogastrogram (EGG) cannot measure the spike potential on the abdominal surface in the time domain. Thus, currently the parameters of EGG adopted by clinical applications are only the characteristics of the slow wave, such as the dominant frequency, the dominant power and the instability coefficients. The limitation of excluding the spike potential analyses hinders EGG from being a diagnosis to comprehensively reveal the motility status of the stomach. To overcome this defect, this paper a) presents an EGG reconstruction method utilizing the specified signal components decomposed by the discrete wavelet packet transform, and b) obtains a frequency band for the human gastric spike potential through fasting and postprandial cutaneous EGG experiments for twenty-five human volunteers. The results indicate the lower bound of the human gastric spike potential frequency is 0.96±0.20 Hz (58±12 cpm), and the upper bound is 1.17±0.23 Hz (70±14 cpm), both of which have not been reported before to the best of our knowledge. As an auxiliary validation of the proposed method, synchronous serosa-surface EGG acquisitions are carried out for two dogs. The frequency band results for the gastric spike potential of the two dogs are respectively 0.83-0.90 Hz (50-54 cpm) and 1.05-1.32 Hz (63-79 cpm). They lie in the reference range 50-80 cpm proposed in previous literature, showing the feasibility of the reconstruction method in this paper.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adaptive independent component analysis of multichannel electrogastrograms.

The electrogastrogram (EGG), a cutaneous measurement of gastric electrical activity, can be severely contaminated by endogenous biological noise sources such as respiratory signal. Therefore it is important to establish effective artifact removal methods. In this paper, a novel blind signal separation method with a flexible non-linearity is introduced and applied to extract the gastric slow wav...

متن کامل

A Time-Domain Method for Shape Reconstruction of a Target with Known Electrical Properties (RESEARCH NOTE)

This paper uses a method for shape reconstruction of a 2-D homogeneous object with arbitrary geometry and known electrical properties. In this method, the object is illuminated by a Gaussian pulse, modulated with sinusoidal carrier plane wave and the time domains’ footprint signal due to object presence is used for the shape reconstruction. A nonlinear feedback loop is used to minimize the diff...

متن کامل

Effects of body mass index on gastric slow wave: a magnetogastrographic study.

We measured gastric slow wave activity simultaneously with magnetogastrogram (MGG), mucosal electromyogram (EMG) and electrogastrogram (EGG) in human subjects with varying body mass index (BMI) before and after a meal. In order to investigate the effect of BMI on gastric slow wave parameters, each subject's BMI was calculated and divided into two groups: subjects with BMI ≤ 27 and BMI > 27. Sig...

متن کامل

A neural mass model of CA1-CA3 neural network and studying sharp wave ripples

We spend one third of our life in sleep. The interesting point about the sleep is that the neurons are not quiescent during sleeping and they show synchronous oscillations at different regions. Especially sharp wave ripples are observed in the hippocampus. Here, we propose a simple phenomenological neural mass model for the CA1-CA3 network of the hippocampus considering the spike frequency adap...

متن کامل

Design of Monophasic Spike-Exponential Waveform for Functional Electrical Stimulator Based on Pulse Width Modulation

The Functional Electrical Stimulator design using monophasic spike-exponential waveform was proposed and described in this study. The monophasic square waveform has benefit in generating an action potential, but it could cause side effects such as toxic caused by the electrode polarization. The square waveform signal which the frequency and pulse width could be modulated was manipulated to be t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Bio-medical materials and engineering

دوره 26 Suppl 1  شماره 

صفحات  -

تاریخ انتشار 2015