Rapid analysis of cefazolin in serum by high-pressure liquid chromatography.

نویسنده

  • J S Wold
چکیده

A high-pressure liquid chromatography (HPLC) method has been developed for the analysis of cefazolin in serum. Serum was deproteinized by the addition of 6% trichloroacetic acid and injected onto a reverse-phase column with a mobile phase of 10 to 15% methanol in 1% aqueous acetic acid. Cefazolin chromatographed without interference from ultraviolet-absorbing components of serum, with a retention time of 3.1 min. Standard curves comparing peak area with concentration prepared from dog or human sera were linear over a range of 1.6 to 200 mug/ml. Results from the HPLC assay were compared with microbiological assays (cylinder plate method) on both standard serum samples and sera from dogs and human subjects receiving intramuscular cefazolin. The HPLC method was somewhat more accurate in comparison with the microbiological assay performed on serum samples of known concentration. The comparison of results from an analysis of serum levels of dogs or human subjects receiving cefazolin indicated that the two methods would lead to identical conclusions concerning pharmacokinetics or the achievement of therapeutic serum levels. The HPLC assay method presents an alternative to conventional microbiological assays, with marked improvement in speed (30 min) and considerable potential for future development.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

Validation of analytical methodology for quantification of cefazolin sodium pharmaceutical dosage form by high performance liquid chromatography to be applied for quality control in pharmaceutical industry

A reversed-phase high performance liquid chromatography method was validated for the determination of cefazolin sodium in lyophilized powder for solution for injection to be applied for quality control in pharmaceutical industry. The liquid chromatography method was conducted on a Zorbax Eclipse Plus C18 column (250 x 4.6 mm, 5 μm), maintained at room temperature. The mobile phase consisted of ...

متن کامل

Interference-free Determination of Carbamazepine in Human Serum Using High Performance Liquid Chromatography: A Comprehensive Research with Three-way Calibration Methods

In the present study, a comprehensive and systematic strategy was described to evaluate the performance of several three-way calibration methods on a bio-analytical problem. Parallel factor analysis (PARAFAC), alternating trilinear decomposition (ATLD), self-weighted alternating trilinear decomposition (SWATLD), alternating penalty trilinear decomposition (APTLD) and unfolded partial least squa...

متن کامل

Interference-free Determination of Carbamazepine in Human Serum Using High Performance Liquid Chromatography: A Comprehensive Research with Three-way Calibration Methods

In the present study, a comprehensive and systematic strategy was described to evaluate the performance of several three-way calibration methods on a bio-analytical problem. Parallel factor analysis (PARAFAC), alternating trilinear decomposition (ATLD), self-weighted alternating trilinear decomposition (SWATLD), alternating penalty trilinear decomposition (APTLD) and unfolded partial least squa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Antimicrobial agents and chemotherapy

دوره 11 1  شماره 

صفحات  -

تاریخ انتشار 1977