Comparative study of different control techniques for the regulation of blood glucose level in diabetic patients.

نویسنده

  • Mohammed S Ibbini
چکیده

Blood glucose regulation is of a great concern for insulin-dependant patients with excessive glucose in blood (hyperglycaemia), or low glucose profile (hypoglycaemia) due to excess insulin delivery. Both conditions can cause dangerous complications for diabetic patients, and hence glucose regulation in blood is of prime importance. Insulin pumps are used to deliver insulin in small quantities, allowing the glucose level to remain as close as possible to that of non-diabetics (near 100 mg dl(-1)). Different control techniques are used to maintain the glucose level and most of them depend on an exact mathematical or empirical model of insulin-glucose interaction. Recently, we have proposed different controllers that are based on fuzzy logic and so do not use mathematical modelling, which in general is nonlinear, complex and suffers from uncertainties. PI fuzzy controllers are physically related to classical PI and PID controllers, which are extremely popular. The parameter settings of classical and fuzzy logic controllers are based on deep common physical background. In this manuscript, a comparative study is proposed to evaluate the use of fuzzy logic controllers over other conventional controllers such as PI and PID controllers to maintain the blood glucose level within a normoglycaemic average especially when a diabetic patient is subjected to different conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

INVESTIGATING THE EFFECT OF COPING TECHNIQUES FOR STRESS AND SELF-REGULATION STRATEGIES ON THE BLOOD GLUCOSE LEVEL OF DIABETIC PATIENTS

Background: the present study aims at investigating the effect of Stress coping techniques and self-regulation strategies on the blood glucose level of diabetic patients. Methods:  the research method was experimentally pretest – posttest with control group. this purpose, out of all those patients who had referred to the Diabetes Center of Bushehr City, 45 diabetic patients were selected rando...

متن کامل

Robust Adaptive Neural Control of the Blood Glucose for Type 1 Diabetic Patients in Presence of Meals

In this paper, the blood glucose control for type 1 diabetic patients in the presence of model uncertainties and uncertain meals is considered. In order to present an efficient control approach, it is assumed that the dynamics describe the mechanism of the blood glucose regulation in type 1 diabetic patients are completely unknown. Hence, based on the universal approximation property of the rad...

متن کامل

Does dietary fish oil improve nerve conduction velocity via regulating of blood glucose level in diabetic rat?

Although it is a well-established fact that dietary fish oil can improve nerve conduction velocity in diabetic rat, but the exact mechanism of its action is unknown. Therefore, in this study we measured the blood glucose level of all animals for evaluating the possible effect of fish oil in improvement of nerve conduction velocity in diabetic neuropathy via regulation of blood glucose level. Fo...

متن کامل

Does dietary fish oil improve nerve conduction velocity via regulating of blood glucose level in diabetic rat?

Although it is a well-established fact that dietary fish oil can improve nerve conduction velocity in diabetic rat, but the exact mechanism of its action is unknown. Therefore, in this study we measured the blood glucose level of all animals for evaluating the possible effect of fish oil in improvement of nerve conduction velocity in diabetic neuropathy via regulation of blood glucose level. Fo...

متن کامل

Chaotic dynamic analysis and nonlinear control of blood glucose regulation system in type 1 diabetic patients

In this paper, chaotic dynamic and nonlinear control in a glucose-insulin system in types I diabetic patients and a healthy person have been investigated. Chaotic analysis methods of the blood glucose system include Lyapunov exponent and power spectral density based on the time series derived from the clinical data. Wolf's algorithm is used to calculate the Lyapunov exponent, which positive val...

متن کامل

Non-invasive Optical Techniques for determination of blood Glucose levels: A Review Article

This article reviews the development of non-invasive optical techniques for determination of blood glucose concentrations in diabetic patients. Early diagnosis and daily management are essential for ensuring the healthy life of diabetic patients. The determination of blood glucose concentration with common devices involves the chemical analysis of blood samples, which are obtained by pricking t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of medical engineering & technology

دوره 33 8  شماره 

صفحات  -

تاریخ انتشار 2009