Measurements of renal glucose release.

نویسنده

  • J E Gerich
چکیده

I am responding to Dr. Weir's query for more details concerning how we handled our raw data in our article " Role of the Human Kidney in Glucose Counter-regulation " (1). Due to high rates of renal blood flow, small arterio-venous differences, and analytical variation, physiologically impossible results such as negative or extremely high fractional extractions (FXs) are not uncommonly observed. These phenomena are not unique to renal experiments, but they can be observed also in splanchnic balance experiments (2). Some investigators, when obtaining physiologically impossible negative renal glucose FXs, have chosen to consider them as zero; other investigators have accepted these data at face value, while others have repeated what they have considered to be erroneous measurements. The first approach seems reasonable, although it would introduce some bias favoring increased renal glucose uptake, which would lead to an increase in the calculation of renal glucose release (RGR). The second approach is very conservative but would have the greatest variance, thereby decreasing the power to detect small changes in RGR. In our studies, we chose the third approach, i.e., to either rerun specific activity or eliminate an obvious statistical outlier among the triplicates of blood glucose concentrations if either a negative or a too high FX value (Ͼ6%) was observed. We used the results of the reruns regardless of outcome to minimize bias. Nevertheless, we realize that our approach is not founded on any statistical precedent and, being somewhat subjective, could lead to biased or even erroneous results. However, we believe that our use of this approach has not led to biased or erroneous results. Our conclusion is based on the reanalysis of our data and the reproducibility of our results by other independent investigators (3) (Table 1). Analysis of the data of our study (1) indicated that 18 of ϳ200 samples initially yielded negative FXs; 13 yielded unrealistically high FXs. With our approach (i.e., reassaying samples or deleting obvious statistical outliers), all high FXs became lower. Fifteen of the negative FXs became less negative while three became more negative. There were still seven negative FXs (3.5% of all determinations). The initial average FX of all these samples changed from 1.4 to 1.8%. However, due to the ro-bustness of equations used to calculate RGR (i.e., changes in glucose concentration produce changes in net balance that affect changes in FX), RGR did not significantly change (1.74 vs. 1.71 ␮mol ⅐ kg …

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of physiological hyperinsulinemia on systemic, renal, and hepatic substrate metabolism.

To determine the effect of physiological hyperinsulinemia on renal and hepatic substrate metabolism, we assessed systemic and renal glucose release and uptake, systemic and renal gluconeogenesis from glutamine, and certain aspects of systemic and renal glutamine and free fatty acid (FFA) metabolism. These were assessed under basal postabsorptive conditions and during 4-h hyperinsulinemic euglyc...

متن کامل

Role of human liver, kidney, and skeletal muscle in postprandial glucose homeostasis.

Recent studies indicate a role for the kidney in postabsorptive glucose homeostasis. The present studies were undertaken to evaluate the role of the kidney in postprandial glucose homeostasis and to compare its contribution to that of liver and skeletal muscle. Accordingly, we used the double isotope technique along with forearm and renal balance measurements to assess systemic, renal, and hepa...

متن کامل

Renal glucose production in the intact dog.

ROSE, DAVID M., JOSEPH DISALVO, AND SULAMITA BALAGURABARUCH. Renal glucose production in the intact dog. Am. J. Physiol. 218(6): 1676-1681. 1970.-Renal glucose production was studied in anesthetized fasting (18 hr) dogs, in various states of acid-base balance, by two procedures: a) by measuring the difference of glucose concentration in renal venous and arterial plasma, using the standard gluco...

متن کامل

Abnormal renal and hepatic glucose metabolism in type 2 diabetes mellitus.

Release of glucose by liver and kidney are both increased in diabetic animals. Although the overall release of glucose into the circulation is increased in humans with diabetes, excessive release of glucose by either their liver or kidney has not as yet been demonstrated. The present experiments were therefore undertaken to assess the relative contributions of hepatic and renal glucose release ...

متن کامل

مقایسه میزان همخوانی یافته‌های سنجش قندخون با استفاده از گلوکومتر ON CALL و گلوکوکارد با روش آزمایشگاهی استاندارد

Background: Diabetes Mellitus (DM) is one the most common chronic disease, with many complications including renal failure, blindness and non traumatic amputation. Prevention of complications is possible through monitoring and control of blood glucose levels. Considering how easy home blood glucose monitoring is, we decided to evaluate the performance of two available glucometers for detection...

متن کامل

بررسی همخوانی نوارهای سنجش قند خون بتاچک با روش استاندارد

Diabetes mellitus (DM) is the commonest cause of renal failure, blindness and non traumatic amputation. According to ADA, prevention of DM complications is possible through monitoring and control of blood glucose levels.Methods: The Betachek strip, produced in Australia, is able to determine biood glucose level with no need for electronic glucometer devices.Results: In this study, we compared v...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Diabetes

دوره 50 4  شماره 

صفحات  -

تاریخ انتشار 2001