Precolumn diastereomerization and micellar electrokinetic chromatography on a plastic microchip: rapid chiral analysis of amino acids.

نویسندگان

  • Kyung Won Ro
  • Jong Hoon Hahn
چکیده

Precolumn derivatization and chiral separation of DL-amino acids based on diastereomerization have been performed on an integrated poly(dimethylsiloxane) microchip. Diastereomeric derivatives were formed in a microfabricated precolumn reactor by the reaction of amino acid enantiomers with o-phthaldialdehyde/2,3,4,6-tetra-O-acetyl-1-thio-beta-D-glucopyranose (OPA/TATG), and separated by MEKC in an achiral environment without chiral selectors in the running buffer. Optimized precolumn reactions and chiral separations of amino acids were achieved within 2.5 min. Resolutions of diastereomers of OPA/TATG-amino acids were in the range of 2.5-6.1 at optimized separation conditions. Simultaneous separation of a mixture of five chiral amino acids was successfully performed in a single run in less than 100 s.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Poly(dimethylsiloxane) microchip for precolumn reaction and micellar electrokinetic chromatography of biogenic amines.

We have demonstrated that precolumn derivatization and capillary electrophoresis separation on a poly(dimethylsiloxane) (PDMS) microchip can be realized as efficient as those on glass microchips. In an optimized condition of micellar electrokinetic chromatography (MEKC), using 25 mM sodium borate buffer (pH 10.0) with 25 mM sodium dodecyl sulfate (SDS) and 5% v/v methanol, the electroosmotic fl...

متن کامل

Use of poly(sodium oleyl-L-leucylvalinate) surfactant for the separation of chiral compounds in micellar electrokinetic chromatography.

A chiral amino acid-based monomeric and polymeric surfactant, sodium oleyl-L-leucylvalinate) (L-SOLV) and poly(sodium oleyl-L-leucylvalinate) (poly-L-SOLV) were synthesized and used for chiral separations in micellar electrokinetic chromatography (MEKC). Poly-L-SOLV was used successfully in the separation of various enantiomers of neutral, acidic, and basic analytes such as 1,1'-bi-2-napthol, 1...

متن کامل

Novel anionic copolymerized surfactants of mixed achiral and chiral surfactants as pseudostationary phases for micellar electrokinetic chromatography.

One disadvantage of amino acid-based chiral selectors for micellar electrokinetic chromatography (MEKC) is that either they have very low solubility or are insoluble at acidic pHs. In order to increase solubilities at lower pHs, we have synthesized a highly water-soluble achiral surfactant and copolymerized it with an amino acid-based chiral surfactant. These two surfactants were polymerized ei...

متن کامل

Quantitation of chiral amino acids from microalgae by micellar electrokinetic chromatography and laser induced fluorescence detection

Running Title: Chiral analysis of microalgae amino acids by MEKC-LIF ABSTRACT In this work, a chiral and a non-chiral micellar electrokinetic chromatography with laser-induced fluorescence detection (MEKC-LIF) have been combined to identify and quantify a group of D-and L-amino acids (D/L-aa) in different microalgae samples. The combination of the non-chiral and chiral-MEKC-LIF methods made eas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Electrophoresis

دوره 26 24  شماره 

صفحات  -

تاریخ انتشار 2005