The importance of humidity in the in vitro study of the cranium with regard to initial bone displacement after force application.

نویسندگان

  • L Govaert
  • L Dermaut
چکیده

The aim of this pilot study was to find a suitable model for simulating in vivo initial displacements of the maxilla after force application. Force was exerted on the maxillae of four dogs by means of a dental splint. To register the bone displacement, speckle interferometry was used as the measurement technique. The initial orthopaedic effect as a result of force application in vivo was registered by the construction of rotation centres around which the maxilla rotated. The orthopaedic effect after force application in vivo was compared with different in vitro situations of the laboratory animal. After the animal had been killed and its maxilla macerated, the cranium was placed in a sealed conditioned box. Only three skulls were found to be suitable for this experiment. The environment thus created can be influenced by changes in relative humidity. Various forces were applied in various directions on the maxilla of three Alsatians. By changing the relative humidity, an attempt was made to create a situation in which the initial bone displacements after force application were comparable to the in vivo situation. None of the laboratory animals used showed a comparable condition for the in vivo situation through manipulation of relative humidity. As only three dogs were experimented on, these findings are tentative. This experiment will be extended to three more dogs from the same litter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تحلیل پایداری ایمپلنت دندانی و بررسی تاثیر عوامل موثر بر اتصال ایمپلنت- استخوان به کمک مدل اصطکاکی تماس

Background and Aims: Relative displacement of the implant with respect to bone and quality of bone-implant contact play critical roles in the dental implant stability. The goal of this study was to investigate the dental implant stability using non-linear finite elements method. Therefore, bone-implant relative displacement due to applied force to the implant was calculated, and then an appropr...

متن کامل

تغییرات موقعیت استخوان هایوئید متعاقب درمان مال اکلوژن class II div1 با دستگاه فانکشنال فرمند1

Background and Aim: Unlike other bones of the head and neck, hyoid bone has no bony articulations. It is connected to mandible, cranium and pharynx through muscles and ligaments. During treatment with functional appliance in patients with class II div1 malocclusion, mandible is positioned in inferior and anterior direction. Regarding the relation between hyoid and mandibular bone, alterations o...

متن کامل

Modeling of Air Relative Humidity Effect on Adhesion Force in Manipulation of Nano-Particles and its Application in AFM

In this paper, the effect of air relative humidity and capillary force on contact geometry of surfaces based on JKR model by Atomic force microscopy was investigated in order to manipulate nano-particles. With transition from macro to nano-scale, the effect of surface forces becomes more significant in comparison with inertial force. Because contact mechanics models are based on surface energy ...

متن کامل

Biomechanical Evaluation of Temperature Rising and Applied Force in Controlled Cortical Bone Drilling: An Animal in Vitro Study

Background: The present study was conducted to quantify the relationships between bone drilling process parameters(i.e., feed rate, resting time, exit rate, and drill bit diameter) and drilling outcome parameters (i.e., thrust force andmaximum temperature).Methods: This study utilized 10-cm cortical bovine samples to evaluate the effects of four independent parameters,in...

متن کامل

Comparative Evaluation of Microleakage at the Interface of Titanium and Zirconium Abutments Following Oblique Cyclic Loading: An in vitro Study

Abstract Background and aim: Oral microbiota could proliferate the microspace between the implant and abutment, thereby cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to investigate the effect of two types of abutments (zirconia and titanium) on microleakage at implant-abutment interface area under oblique cyclic loading in vitro. Materials and methods:In thi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of orthodontics

دوره 19 4  شماره 

صفحات  -

تاریخ انتشار 1997