Mid-term Follow-up of the Transcatheter Closure of Perimembranous Ventricular Septal Defects in Children Using the Amplatzer.

نویسندگان

  • Mehdi Ghaderian
  • Mahmood Merajie
  • Hodjjat Mortezaeian
  • Mohammad Yoosef Aarabi Moghadam
  • Akbar Shah Mohammadi
چکیده

BACKGROUND The ventricular septal defect (VSD) is the most common form of congenital heart defects. The purpose of this study was to evaluate the results of the early complications and mid-term follow-up of the transcatheter closure of the VSD using the Amplatzer VSD Occluder. METHODS Between April 2012 and October 2013, 110 patients underwent the percutaneous closure of the perimembranous VSD. During the procedure, the size and type of the VSD were obtained via ventriculography. A device at least 2 mm larger than the VSD diameter measured via ventriculography was deployed. The size of the VSD, size of the Amplatzer, and device-size to VSD-size ratio were calculated. After the confirmation of the suitable position of the device via echocardiography and left ventriculography, the device was released. Follow-up evaluations were done at discharge as well as at 1, 6, and 12 months and yearly thereafter for the VSD occlusion and complete heart block. RESULTS The study population comprised 62 females and 48 males. The mean age and weight of the patients at procedure were 4.3 ± 5.6 years (range: 2 to 14) and 14.9 ± 10.8 kg (range: 10 to 43). The average device size was 7.0 ± 2.5 mm (range: 4 to 14). The VSD occlusion rate was 72.8% at the completion of the procedure and rose up to 99.0% during the follow-up. The most serious significant complication was complete atrioventricular block, which was seen in 2 patients. The mean follow-up duration was 10.9 ± 3.6 months. CONCLUSION The transcatheter closure of the perimembranous VSD was a safe and effective treatment with excellent closure rates in our study population. This procedure had neither mortality nor serious complications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcatheter device closure of perimembranous ventricular septal defects: mid-term outcomes

AIMS The aim of this study was to evaluate the safety and efficacy of transcatheter closure for perimembranous ventricular septal defect (pmVSD) and its long-term results. The most common congenital heart condition is pmVSD. Transcatheter closure of pmVSD is a recently described technique with limited results for mid- to long-term follow-up. METHODS AND RESULTS Between June 2002 and June 2008...

متن کامل

Efficacy and Safety of Using Amplatzer Ductal Occluder for Transcatheter Closure of Perimembranous Ventricular Septal Defect in Pediatrics

BACKGROUND Perimembranous Ventricular Septal Defect (PMVSD) is the most common subtype of ventricular septal defects. Transcatheter closure of PMVSD is a challenging procedure in management of moderate or large defects. OBJECTIVES The purpose of this study was to show that transcatheter closure of perimembranous ventricular septal defect with Amplatzer Ductal Occluder (ADO) is an effective an...

متن کامل

Transcatheter closure of perimembranous ventricular septal defects.

The isolated perimembranous ventricular septal defect is one of the most common congenital cardiac malformations. Although surgery has been performed and has a low associated risk, it still involves morbidity due to factors such as residual leaks, atrioventricular block, postpericardiotomy syndrome and arrhythmias. It has been speculated that percutaneous closure of these defects could minimize...

متن کامل

Transcatheter closure of perimembranous ventricular septal defects with the Amplatzer asymmetric ventricular septal defect occluder: preliminary experience in children.

OBJECTIVE To close perimembranous ventricular septal defects (PMVSDs) in children with the new Amplatzer asymmetric ventricular septal defect occluder (AAVSDO). PATIENTS AND DESIGN 10 children, aged 1.5-12 years, with PMVSDs underwent transcatheter closure with the AAVSDO. The device consists of two low profile disks made of Nitinol wire mesh with a 1.5 mm connecting waist. The left disk is 5...

متن کامل

Transcatheter closure of iatrogenic perimembranous ventricular septal defect after aortic valve and ascending aorta replacement using an Amplatzer membranous ventricular septal occluder.

Iatrogenic perimembranous ventricular septal defect is a rare complication after surgical replacement of the aortic valve, and so transcatheter closure of such a defect is not a routine procedure. We report the successful closure of an iatrogenic perimembranous ventricular septal defect which occurred after the replacement of the aortic valve and ascending aorta.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of Tehran Heart Center

دوره 10 4  شماره 

صفحات  -

تاریخ انتشار 2015