Comparative Evaluations of 3d Turbo Spin Echo (tse) Motion Sensitized Driven Equilibrium (msde) and 2d Double Inversion Recovery Tse Sequences for T1-weighted Black-blood Carotid Atherosclerosis Imaging
نویسندگان
چکیده
Introduction In vivo MR carotid plaque imaging has been used to identify vessel morphology and plaque characteristics, and their associations with clinical symptoms. [1] Two-dimensional T1 weighted (T1W) double inversion recovery spin echo [2] and subsequently quadruple inversion recovery spin echo sequences [3] have been used to obtain the contrast between vessel wall and lumen, and identify carotid artery morphology. Although these sequences provide sufficiently blood-suppressed images, relatively longer scan time limits the number of scan slices. A turbo-spin echo (TSE) based motion sensitized driven equilibrium (MSDE) was proposed as an alternative black-blood carotid MR imaging scheme [4]. MSDE sequence enables black-blood images without cardiac gating and can be combined with 3-dimensional (3D) image acquisition. 3D acquisition enables reformatted images in any arbitrary plane, which would be helpful for evaluating tortuous carotid anatomy. In addition, it has the potential to obtain accurate co-registration of images acquired in different time points We have optimized a 3D-TSE based MSDE (3D MSDEVolume Isotropic Acquisition (VISTA)) sequence as an alternative method for carotid MR imaging. The purpose of this study is to compare 3D T1W MSDE-VISTA and 2D T1W DIR TSE for signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), and to determine if 3D MSDE-VISTA is potential replacement for conventional carotid 2D DIR TSE carotid plaque imaging. Materials and Methods Five healthy volunteers (age range, 28–33 years) and 3 (age mean, 68) patients with known>15% stenosis by carotid ultrasound underwent carotid wall MR imaging. All examinations were performed with Intera Achieva Quasar Dual 3.0T R2 (Philips medical systems) and a 2-channel SENSE FLEX-S coil (Philips medical systems). Pre-contrast T1W images of 3D MSDE-VISTA and 2D DIR TSE sequences were acquired for all the subjects. After intravenous injection of gadolinium (Magnescope,dose, 0.2ml/kg), contrast-enhanced T1 images of 3D MSDE-VISTA and 2D DIR TSE using the same parameters were acquired in the 3 patents. The following details scan parameters of each sequence. 3D MSDE VISTA acquisition parameters: Figure 1 illustrates MSDE preparation consisting of 90° excitation pulse, 180° refocusing pulse and -90° flip back pulse with motion sensitizing gradients sandwiched in between RF pulses. MSDE preparation time (Prep TE) was set to 12.1ms and velocity encoding was set to 3.8cm/s. TSE followed the MSDE preparation for the data acquisition. TR/TE=617/7.6ms, flip angle=90°, turbo factor (TF) = 10, SENSE factor (SF) = 1.3, number of signals averaged (NSA) = 1, field of view (FOV) =16*16cm, matrix = 256*204, slice thickness =2mm, number of slices = 16. Scan time=4min48sec. 2D DIR TSE acquisition parameters: TR/TE=1000/10ms, TI=420ms, TF=7. NSA=4. FOV=16*16cm, matrix = 256*204, slice thickness =2mm. Three slices positioned at the center of 3D MSDE-VISTA imaging volume were acquired. Scan time=5min30s (110s/slice, heart rate of 60 beats per minute) Data analysis: Intensity data were collected from each matched location. The mean signal intensities (SIs) of the lumen and vessel wall (fibrous tissue) along with the mean SIs with standard deviations (SDs) were documented. SNRs of the lumen and wall and CNRs (wall/lumen) were calculated. All the SNRs and CNRs were compared between 3D MSDE-VISTA and 2D DIR TSE images using a paired t test. P<0.05 was designated as the statistical significance. Results All the subjects were successfully imaged. Table 1 detailed results of comparison of SNRs of the lumen and wall and CNRs between 3D MSDE-VISTA and 2D DIR TSE sequences. With regarding to the comparison of precontrast T1W sequences for matched 24 slices in all the 8 subjects, 3D MSDE-VISTA demonstrated significantly higher CNR (p<0.001), and significantly lower lumen SNR (p<0.01) than those in 2D DIR TSE. For postcontrast T1Wsequences, 9 slices in 3 patients were matched for comparison. Lumen SNR was significantly lower in 3D MSDE-VISTA
منابع مشابه
Improvement of T1 contrast in whole-brain black-blood imaging using motion-sensitized driven-equilibrium prepared 3D turbo spin echo (3D MSDE-TSE).
We demonstrated a new scheme for performing the T1-enhanced whole-brain black-blood imaging pulse sequence using motion-sensitized driven-equilibrium prepared 3-dimensional (3D) turbo spin echo (MSDE-TSE) with anti-driven-equilibrium post pulse. The use of an anti-driven-equilibrium pulse considerably improved the T1 contrast of MSDE-TSE black-blood images. This sequence can be used for whole-b...
متن کاملClinical Assessment of motion sensitized driven equilibrium (MSDE) prepared T1W 3D vessel wall imaging at 3.0T for soft plaque screening
INTRODUCTION: Motion sensitized driven equilibrium (MSDE) prepared sequence has been proposed for fast black-blood vessel wall imaging (1, 2). Moreover, for detection of different kinds of plaques at the carotid artery wall, MSDE prepared 3D gradient echo sequence, optimized both for T1 and T2 contrasts, was proposed (3). This method allows wider anatomical coverage in short acquisition time co...
متن کاملFree-breathing 3D whole-heart black-blood imaging with motion sensitized driven equilibrium.
PURPOSE To assess the efficacy and robustness of motion sensitized driven equilibrium (MSDE) for blood suppression in volumetric 3D whole-heart cardiac MR. MATERIALS AND METHODS To investigate the efficacy of MSDE on blood suppression and myocardial signal-to-noise ratio (SNR) loss on different imaging sequences, seven healthy adult subjects were imaged using 3D electrocardiogram (ECG)-trigge...
متن کاملDiagnosis of Brain Metastasis:Feasibility and Efficacy of Motion-Sensitized Driven-Equilibrium(MSDE) Turbo Spin-Echo Sequence
Introduction In this study, a turbo spin-echo with a motion-sensitized driven-equilibrium (MSDE) sequence was used as an alternative head MR imaging technique for brain metastasis. Post-contrast 3D T1-weighted imaging is routinely used to detect brain metastasis. In those images, high signal intensity of blood vessels is a disturbing factor, since it can be mistaken for enhancement of metastati...
متن کامل3D turbo spin-echo sequence with motion-sensitized driven-equilibrium preparation for detection of brain metastases on 3T MR imaging.
BACKGROUND AND PURPOSE MSDE preparation is a technique for black-blood imaging. Our purpose was to evaluate the usefulness of a 3D TSE sequence with MSDE preparation in detecting brain metastases by comparing it with conventional sequences. MATERIALS AND METHODS Postcontrast images of 227 patients who were suspected of having brain metastasis were prospectively obtained by using 3 T1-weighted...