Using lateral radiographs to determine umbilical venous catheter tip position in neonates.
نویسندگان
چکیده
We aimed to assess the difference in measurement of the distance of the UVC tip from the diaphragm between (Anteroposterior) AP and lateral radiographs and to determine the reliability of the measurement of UVC tip distance from the diaphragm between the two views. A retrospective review of paired AP and lateral radiographs taken to assess UVC tip position was carried out in 25 infants was conducted and reliability analysis was carried out. There was a significant difference in the mean (SD) distance of the UVC catheter above the diaphragm between the AP and lateral radiographs: 8.7 (7.8) mm versus 11.6 (7.3) mm (p = 0.003) respectively. Measurements using lateral radiographs were more reliable (Intraclass correlation coefficient: 0.99 vs. 0.93). Inter-observer reliability analysis yielded similar results. Lateral radiographs are more reliable in measurement of UVC tip position and should be performed in conjunction with AP films to aid in determining UVC position.
منابع مشابه
Comparing the anatomy of the intrathoracic systemic central venous system in Iranian pediatrics and adults based on chest CT scan and evaluation of rate of catheter malposition in children
Background: Central venous catheterization is a procedure that is being performed frequently especially in critical clinical settings. In such conditions, good knowledge of the surface anatomy of venous structures is vital to avoid possible complications which could result in life-threatening situations such as bleeding and pneumothorax. Considering the difference between venous anatomy of chil...
متن کاملAccuracy of chest radiography for positioning of the umbilical venous catheter.
OBJECTIVES To evaluate the accuracy of the simultaneous analysis of three radiographic anatomical landmarks - diaphragm, cardiac silhouette, and vertebral bodies - in determining the position of the umbilical venous catheter distal end using echocardiography as a reference standard. METHODS This was a cross-sectional, observational study, with the prospective inclusion of data from all neonat...
متن کاملPoor Accuracy of Methods Currently Used to Determine Umbilical Catheter Insertion Length
This study compares the methods of Dunn and Shukla in determining the appropriate insertion length of umbilical catheters. In July 2007, we changed our policy for umbilical catheter insertions from the method of Dunn to the method of Shukla. We report our percentage of inaccurate placement of umbilical-vein catheters (UVCs) and umbilical-artery catheters (UACs) before and after the change of po...
متن کاملCardiac tamponade in a newborn because of umbilical venous catheterization: is correct position safe?
Cardiac tamponade is a rare but life-threatening complication of umbilical venous catheterization in the newborn. Most complications from central venous catheters are related to incorrect position of the catheter and it is emphasized to confirm the position of the catheter tip after placement in order to avoid possible complications. We present an unusual complication of cardiac tamponade becau...
متن کاملAre supine chest and abdominal radiographs the best way to confirm PICC placement in neonates?
BACKGROUND Peripherally inserted central catheters (PICCs) are commonly used in NICUs. Although they have many benefits, they also have many potential complications. Confirming catheter tip position is essential to decreasing complications, but the best method to achieve confirmation is unclear. OBJECTIVES Literature review for studies that address line position confirmation to assist health ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Irish medical journal
دوره 107 8 شماره
صفحات -
تاریخ انتشار 2014