Study and optimal correction of a systematic skew quadrupole field in the Tevatron
نویسندگان
چکیده
Increasing demands for luminosity in existing and future colliders have made lattice design and error tolerance and correction critical to achieving performance goals. The current state of the Tevatron collider is an example, with a strong skew quadrupole error present in the operational lattice. This work studies the high-order performance of the Tevatron and the strong nonlinear behavior introduced when a significant skew quadrupole error is combined with conventional sextupole correction, a behavior still clearly evident after optimal tuning of available skew quadrupole circuits. An optimization study is performed using different skew quadrupole families, and, importantly, local and global correction of the linear skew terms in maps generated by the code COSY INFINITY [M. Berz, COSY INFINITY version 8.1 user’s guide and reference manual, Department of Physics and Astronomy MSUHEP-20704, Michigan State University (2002). URL http://cosy.pa.msu.edu/cosymanu/index.html]. Two correction schemes with one family locally correcting each arc and eight independent correctors in the straight sections for global correction are proposed and shown to dramatically improve linearity and performance of the baseline Tevatron lattice. Published by Elsevier B.V. PACS: 02.60.Pn; 29.20. c; 29.27. a; 29.85.+c
منابع مشابه
Skew Quadrupole Focusing Lattices and Applications
In this paper we revisit using skew quadrupole fields in place of traditional normal upright quadrupole fields to make beam focusing structures. We illustrate by example skew lattice decoupling, dispersion suppression and chromatic correction using the neutrino factory Study-II muon storage ring design. Ongoing BNL investigation of flat coil magnet structures that allow building a very compact ...
متن کاملCorrection of the Betatron Coupling and Closed Orbit Distortion at the Vepp-2000 Collider
An essential condition for the round beam mode operation at the VEPP-2000 storage ring is the zero betatron coupling in the arc between two Interaction Points. To comply with this requirement the closed orbit should be corrected and the proper skew quadrupole correction system must exist. This work presents the development of the dipole and skew quadrupole correction systems for VEPP-2000. The ...
متن کاملBeam Performance_RF2009_Beam Performance
The vertical beam spread is one of the most important parameters for the high brilliance storage ring, which is represented by the coupling ratio of the horizontal and vertical beam emittances. The coupling between the horizontal and vertical betatron oscillations and the vertical dispersion with the energy spread generate the vertical beam spread, so that they should be corrected. The latter h...
متن کاملThe Coupling Correction System at Rhic: Results for the Run 2000 and Plans for 2001*
The RHIC coupling correction system has been commissioned during the Year 2000 run, which marked the successful first year of operation of the machine. The RHIC coupling correction system is described with particular emphasis on its flexibility, which allows using both global and local coupling compensation techniques. Coupling measurements and correction data are presented for the RHIC Blue an...
متن کاملReview of transmission scanning configurations in cardiac SPECT
The diagnostic accuracy of single photon emission computed tomography (SPECT) is profoundly influenced by attenuation phenomenon. Soft tissue attenuation degrades cardiac SPECT image quality, thereby decreasing the possibility of the detection of the lesions. A variety of correction techniques based on different assumptions have been used to reduce the impact of attenuation. Several types of sy...
متن کامل