OSART Good Practices

ثبت نشده
چکیده

Comprehensive quality control information system is effectively used to plan, perform, track and evaluate quality control related laboratory activities and some other chemistry duties. This system allows to the performing of the following functions:-Recording of non-standardized samples.-Recording of analytical procedures.-Recording of calibration results.-Calculation of analytical errors.-Automatic recording of calibration and check results of laboratory pipetting equipment by direct communication with analytical balances.-Quality control charts calculation and displaying.-Recording of issued protocols.-Recording of standards and laboratory chemicals storage and consumption with expiration time alerts.-Recording of instrument handbooks and logbooks.-Recording of shift reports.-Recording of walk down, audit and assessment inconsistencies.-Functional dependences of different chemistry and other relevant parameters.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

OSART Good Practices

PROSUR and SIAT Programs It is important that document and procedure configuration controls be managed closely to adequately promote reactor safety. The PROSUR and SIAT Programs provide important elements of this control. PROSUR The Prosur program is a single reference program that encompasses all plant system activities, for example: maintenance, operations, chemistry, surveillance tests. The ...

متن کامل

OSART Good Practices

The principal leak detection system for primary to secondary leaks is monitoring of the Nitrogen-16 activity in the live steam at the exit of the steam generators (SG). This is supplemented by tritium measurement in the condensate or feedwater, Xenon measurement in the incondensible gases exhausted from the condenser and radioelement detection in the steam generator blowdowns. Tritium is especi...

متن کامل

OSART MISSION HIGHLIGHTS 2003-2006 r1

The material in this document has been supplied by the authors and has not been edited by the IAEA. The view expressed remains the responsibility of the named authors and do not necessarily reflect those of the government(s) of the designating Member States(s). In particular, neither the IAEA nor any other organization or body sponsoring this meeting(s) can be held responsible for any material ...

متن کامل

Major Barriers to Application of Good Agricultural Practices (GAPs) Technologies in Sustainability of Livestock Units

The main purpose of this study was to investigate the major barriers to application of Good Agricultural Practices (GAPs) technologies in sustainability of livestock by ranchers of Meshkinshahr. A sample of 120 farmers was selected by using proportional random sampling method. Data were collected by means of a questionnaire. Validity of questionnaire was determined through Agricultural Jihad ex...

متن کامل

OSART Good Practices

Application of a Laboratory Information and Management System called MERLIN for the diverse jobs of a laboratory from taking samples to data evaluation. With the MERLIN application the plant has:-easily integrated corporate chemistry specifications-adjusted them to plant specifics, setting of more restrictive thresholds, setting specifications per type, date and frequency-adjusted them to the l...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014