MgB2 SQUID for Magnetocardiography

نویسندگان

  • Yoshitomo Harada
  • Koichiro Kobayashi
  • Masahito Yoshizawa
چکیده

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-Tc SQUID gradiometer system for magnetocardiography in an unshielded environment

We set up an electronic gradiometer for magnetocardiography (MCG) in an unshielded environment. The electronically balanced gradiometer consists of high-temperature radio-frequency superconducting quantum interference device (rf SQUID) magnetometers. The rf SQUID magnetometers are arranged to form the electronic first-order, four-vector gradiometer, or second-order gradiometer. The output of th...

متن کامل

Development and Applications of SQUIDs in Korea

As sensitive magnetic sensors, magnetometers based on superconducting quantum interference devices can be used for the detection of weak magnetic fields. These signals can be generated by diverse origins, for example, brain electric activity, myocardium electric activity, and nuclear precession of hydrogen protons. In addition, weak current induced in the low-temperature detectors, for example,...

متن کامل

Superconducting Quantum Interference Device: The Most Sensitive Detector of Magnetic Flux

SQUIDs are the most sensitive devices in detecting the magnetic flux. The devices have been used to detect small magnetic field, current, voltage, inductance and magnetic susceptibility etc. In this work, we reported studies and applications of high-Tc YBa2Cu3Oy SQUIDs. Two main techniques of depositing YBCO thin films are described; the characteristic of thin film and high-Tc SQUID are address...

متن کامل

A compact, high performance atomic magnetometer for biomedical applications.

We present a highly sensitive room-temperature atomic magnetometer (AM), designed for use in biomedical applications. The magnetometer sensor head is only 2 × 2 × 5 cm3 and is constructed using readily available, low-cost optical components. The magnetic field resolution of the AM is <10 fT Hz–1/2, which is comparable to cryogenically cooled superconducting quantum interference device (SQUID) m...

متن کامل

Closed - cycle gas flow system for cooling of high T , d . c . SQUID magnetometers

A high T, d.c. SQUID based magnetometer for magnetocardiography is currently under development at the University of Twente. Since such a magnetometer should be simple to use, the cooling of the system can be realized most practically by means of a cryocooler. A closed-cycle gas flow cooling system incorporating such a cooler has been designed, constructed and tested. The aimed resolution of the...