Monitoring unfractionated heparin with the aPTT: time for a fresh look.

نویسندگان

  • John W Eikelboom
  • Jack Hirsh
چکیده

Laboratory monitoring is widely recommended to measure the anticoagulant effect of unfractionated heparin and to adjust the dose to maintain levels in the target therapeutic range. The most widely used laboratory assay for monitoring unfractionated heparin therapy is the activated partial thromboplastin time (aPTT). A fixed therapeutic range for the aPTT of 1.5 to 2.5 times the control value has become widely accepted, but the evidence supporting this range is weak and the clinical validity of using the aPTT for predicting thrombotic or bleeding events is questionable. The aPTT test is also affected by numerous preanalytic and analytic variables that are unrelated to the anticoagulant effect of unfractionated heparin, further eroding its potential value for monitoring unfractionated heparin treatment. Unfractionated heparin dose appears to be more important than the aPTT in predicting clinical efficacy. Despite serious limitations, the reliance on the aPTT is likely to continue because of its ready availability and familiarity of clinicians with the test. The focus of clinicians who manage unfractionated heparin therapy should be to ensure that an adequate starting dose of unfractionated heparin is used and that the aPTT method is standardized. Future research efforts should be directed towards developing methods to improve standardization of the aPTT assay for monitoring unfractionated heparin. Direct measures of the concentration of unfractionated heparin in the blood are attractive because these assays are not affected by many of the biologic variables that interfere with the aPTT and may be suitable for automation. However, currently available unfractionated heparin assays are much more expensive than the aPTT, are not widely available, and their validity has not been adequately assessed in clinical outcome studies.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lack of correlation between heparin dose and standard clinical monitoring tests in treatment with unfractionated heparin in critically ill children.

UNLABELLED The activated partial thromboplastin time (aPTT) and anti-Xa activity are used for monitoring unfractionated heparin (UFH) therapy in children and may not be optimal. OBJECTIVE Determine correlations of aPTT, anti-Xa and UFH dose in children. Single centre prospective cohort study in children receiving UFH. The aPTT and anti-Xa results from routine coagulation monitoring were colle...

متن کامل

Concordance between Activated Partial Thromboplastin Time and Antifactor Xa Assay for Monitoring Unfractionated Heparin in Hospitalized Hyperbilirubinemic Patients.

BACKGROUND Activated partial thromboplastin time (aPTT) and antifactor Xa (anti-Xa) monitoring methods for unfractionated heparin (UFH) often disagree. The extent of discordance for those with elevated bilirubin remains unclear. Our objective was to evaluate concordance between activated aPTT and anti-Xa methods for hyperbilirubinemic patients on UFH. METHODS This was a retrospective cohort s...

متن کامل

Establishing the heparin therapeutic range using aPTT and anti-Xa measurements for monitoring unfractionated heparin therapy

BACKGROUND Unfractionated heparin (UFH) has unstable pharmacokinetics and requires close monitoring. The activated partial thromboplastin time (aPTT) test has been used to monitor UFH therapy for decades in Korea, but its results can be affected by numerous variables. We established an aPTT heparin therapeutic range (HTR) corresponding to therapeutic anti-Xa levels for continuous intravenous UF...

متن کامل

Accuracy of aPTT monitoring in critically ill patients treated with unfractionated heparin.

INTRODUCTION The anticoagulant effect of unfractionated heparin (UFH) is usually monitored by means of the activated partial thromboplastin time (aPTT). In critically ill patients, however, increased levels of acute phase proteins may decrease the accuracy of the aPTT, leading to inadequate UFH dosing. In these circumstances, the anti-Xa assay is recommended for monitoring. OBJECTIVE We aimed...

متن کامل

The PiCT® test is a reliable alternative to the activated partial thromboplastin time in unfractionated heparin therapy management: results from a multicenter study.

Essentials Activated partial thromboplastin time (APTT) or anti-Xa tests are used to monitor heparin. Prothrombinase-induced Clotting Time (PiCT) was compared to APTT in a clinical study. PiCT shows higher correlation to anti-Xa than APTT does and is more comparable between centers. PiCT demonstrates significantly higher accuracy and reliability than APTT in heparin monitoring. SUMMARY Backgr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Thrombosis and haemostasis

دوره 96 5  شماره 

صفحات  -

تاریخ انتشار 2006