A randomized study of remote follow-up of implantable cardioverter defibrillators: safety and efficacy report of the ECOST trial

نویسندگان

  • Laurence Guédon-Moreau
  • Dominique Lacroix
  • Nicolas Sadoul
  • Jacques Clémenty
  • Claude Kouakam
  • Jean-Sylvain Hermida
  • Etienne Aliot
  • Michel Boursier
  • Olivier Bizeau
  • Salem Kacet
چکیده

AIMS The ECOST trial examined prospectively the long-term safety and effectiveness of home monitoring (HM) of implantable cardioverter defibrillators (ICD). METHODS AND RESULTS The trial's primary objective was to randomly compare the proportions of patients experiencing ≥ 1 major adverse event (MAE), including deaths from all causes, and cardiovascular, procedure-related, and device-related MAE associated with HM (active group) vs. ambulatory follow-ups (control group) in a sample of 433 patients. The 221 patients assigned to the active group were seen once a year, unless HM reported an ICD dysfunction or a clinical event requiring an ambulatory visit, while the 212 patients in the control group underwent ambulatory visits every 6 months. The characteristics of the study groups were similar. Over a follow-up of 24.2 months, 38.5% of patients in the active and 41.5% in the control group experienced ≥ 1 MAE (P < 0.05 for non-inferiority). The overall number of shocks delivered was significantly lower in the active (n = 193) than in the control (n = 657) group (P < 0.05) and the proportion of patients who received inappropriate shocks was 52% lower in the active (n = 11) than in the control (n = 22) group (P < 0.05). At the end of the follow-up, the battery longevity was longer in the active group because of a lower number of capacitor charges (499 vs. 2081). CONCLUSION Our observations indicate that long-term HM of ICD is at least as safe as standard ambulatory follow-ups with respect to a broad spectrum of MAE. It also lowered significantly the number of appropriate and inappropriate shocks delivered, and spared the device battery. Clinical trials registration NCT00989417.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Current clinical evidence for remote patient management.

Pacemaker (PM) and implantable cardioverter defibrillator (ICD) patients are ideally suited to remote management in the form of remote follow-up as well as of remote monitoring, which are both acts of telemedicine. Large randomized trials, such as TRUST, COMPAS, CONNECT, ECOST and EVOLVO, and the huge ALTITUDE registry provided a high level of evidence for the multiple advantages of remote mana...

متن کامل

Costs of remote monitoring vs. ambulatory follow-ups of implanted cardioverter defibrillators in the randomized ECOST study

AIMS The Effectiveness and Cost of ICD follow-up Schedule with Telecardiology (ECOST) trial evaluated prospectively the economic impact of long-term remote monitoring (RM) of implantable cardioverter defibrillators (ICDs). METHODS AND RESULTS The analysis included 310 patients randomly assigned to RM (active group) vs. ambulatory follow-ups (control group). Patients in the active group were s...

متن کامل

THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL

Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...

متن کامل

Effectiveness and safety of remote monitoring of patients with an implantable loop recorder.

INTRODUCTION AND OBJECTIVES Implantable loop recorders have proven efficacy in the study of patients with syncope and palpitations. Remote monitoring of patients with pacemakers and implantable cardioverter-defibrillators has been shown to be safe and effective. The purpose of this study was to analyze the safety and effectiveness of remote monitoring in patients with an implantable loop record...

متن کامل

Arrhythmia/Electrophysiology Efficacy and Safety of Automatic Remote Monitoring for Implantable Cardioverter-Defibrillator Follow-Up The Lumos-T Safely Reduces Routine Office Device Follow-Up (TRUST) Trial

Background—Monitoring implantable cardiac device function and patient condition is important. The Lumos-T Safely Reduces Routine Office Device Follow-Up (TRUST) trial tested the hypothesis that remote home monitoring with automatic daily surveillance (HM) is safe and effective for implantable cardioverter-defibrillator follow-up for 1 year and enables rapid physician evaluation of significant e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 34  شماره 

صفحات  -

تاریخ انتشار 2013