Measurement of wheelchair rolling resistance with a handle bar push technique.

نویسندگان

  • L H V van der Woude
  • C Geurts
  • H Winkelman
  • H E J Veeger
چکیده

The purpose of this study was to evaluate a technique of pushing a wheelchair at the level of the handle bars as a method for measuring rolling resistance of wheelchair-user systems under different field conditions. Under standardized conditions on a motor driven treadmill, rolling resistance was determined using a 2D strain gauge-based push technique at the level of the handle bars and a commonly used 1D strain gauge-based wheelchair drag test using an adapted push wheelchair and ISO dummy at several velocities and using different push handle heights. After verification of the method, rolling resistance of six different floor surfaces was measured with the experimental push wheelchair in a centre for rehabilitation. Using an analysis of variance for repeated measures, small but significant differences in rolling resistance were found between the drag and push tests on a motor driven treadmill. Belt velocity and push handle height significantly affected rolling resistance. In the field study in the rehabilitation centre, tiles and tarpaulin had the lowest rolling resistance, while high piled carpet had the highest values. It is concluded that the wheelchair pushing method described in this study is usable for the determination of (relative) differences in rolling resistance of different floor materials if performed under standardized conditions and procedures, such as a stable velocity (within a small range of variation), using an ISO-dummy and a constant pushing handle bar height.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Modification of One Arm Driven Manual Hemiplegic Wheelchair

This paper presents design modification to the existing standard wheelchair by incorporating an improved propulsion system and also braking and tilting systems that allow its full control with only one hand. The proposed design has the propulsion system with a chain drive powered through a four-bar linkage driven by the main handle. The desired direction of motion is obtained by moving the leve...

متن کامل

A technique for the determination of center of gravity and rolling resistance for tilt-seat wheelchairs.

A balance platform setup was defined for use in the determination of the center of gravity in the sagittal plane for a wheelchair and patient. Using the center of gravity information, measurements from the wheelchair and patient (weight, tire coefficients of friction), and various assumptions (constant speed, level-concrete surface, patient-wheelchair system is a rigid body), a method for estim...

متن کامل

Wheelchair tire rolling resistance and fatigue.

The hysteresis loss theory of rolling resistance is developed for solid rubber wheelchair tires. The analysis is used to correlate test data for a clay-filled natural rubber and a polyurethane tire material. A discussion of tire rolling work, hysteresis loss factor measurement, and rolling loss measurement is presented. An example calculation of rolling resistance for a polyurethane tire is giv...

متن کامل

Effect of push handle height on net moments and forces on the musculoskeletal system during standardized wheelchair pushing tasks.

The aim of this investigation was to analyze the external forces and biomechanical loading on the musculoskeletal system during wheelchair pushing, in relation to different push handle heights. In addition, recommendations for wheelchair pushing in accordance with push handle height are made. Eight young, female subjects carried out three different wheelchair transport tasks at five different p...

متن کامل

Evaluation of wheelchair tire rolling resistance using dynamometer-based coast-down tests.

The objective of this study was to compare the rolling resistance of four common manual wheelchair tires (two pneumatic and two airless solid) and the solid tires used on a commercially available force- and moment-sensing wheel. Coast-down tests were performed with a wheelchair positioned on a two-drum dynamometer. Within each of three load conditions, tire type had a significant effect on roll...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of medical engineering & technology

دوره 27 6  شماره 

صفحات  -

تاریخ انتشار 2003