Anti-factor Xa and activated partial thromboplastin time measurements for heparin monitoring in mechanical circulatory support.

نویسندگان

  • Sirtaz Adatya
  • Nir Uriel
  • Hirad Yarmohammadi
  • Christopher T Holley
  • Amy Feng
  • Samit S Roy
  • Mark T Reding
  • Ranjit John
  • Peter Eckman
  • Nicole D Zantek
چکیده

OBJECTIVES This study investigated the relationship between anti-factor Xa (anti-FXa) and activated partial thromboplastin time (aPTT) for monitoring intravenous unfractionated heparin (IV-UFH) in patients with continuous-flow left ventricular assist devices (CF-LVADs). BACKGROUND CF-LVADs have become mainstream therapy for patients with advanced heart failure. Thromboembolic events, device thrombosis, and bleeding continue to be a challenge with this technology. Adequate anticoagulation is required to prevent these adverse events. METHODS A prospective study of consecutive patients implanted with a CF-LVAD was conducted. Paired samples were considered concordant if aPTT values fell into expected ranges for subtherapeutic, therapeutic, and supratherapeutic anti-FXa levels. Heparin dosing was on the basis of anti-Xa levels. RESULTS A total of 340 paired values from 38 patients were evaluated. Anti-FXa and aPTT were discordant in 253 samples (74.4%), with a high degree of variability in aPTT for any given anti-FXa level (r(2) = 0.57). Results were discordant in 104 samples (63.8%) from patients undergoing bridging therapy with warfarin and in 149 samples (84.2%) from patients with device obstruction and/or hemolysis (p < 0.001). The most common pattern of discordance was a supratherapeutic aPTT value despite a therapeutic anti-FXa level (49.1% for bridging vs. 75.8% for device obstruction and/or hemolysis; p < 0.001). CONCLUSIONS Levels of aPTT were disproportionately prolonged relative to the corresponding anti-FXa levels in CF-LVAD patients, particularly those with device obstruction. Hemolysis and warfarin administration may falsely elevate aPTT, resulting in overestimation of heparin concentration and under-anticoagulation. Use of aPTT and anti-FXa to guide heparin therapy may lead to different estimates of heparin concentration in the same patient.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lack of correlation between heparin dose and standard clinical monitoring tests in treatment with unfractionated heparin in critically ill children.

UNLABELLED The activated partial thromboplastin time (aPTT) and anti-Xa activity are used for monitoring unfractionated heparin (UFH) therapy in children and may not be optimal. OBJECTIVE Determine correlations of aPTT, anti-Xa and UFH dose in children. Single centre prospective cohort study in children receiving UFH. The aPTT and anti-Xa results from routine coagulation monitoring were colle...

متن کامل

Concordance between Activated Partial Thromboplastin Time and Antifactor Xa Assay for Monitoring Unfractionated Heparin in Hospitalized Hyperbilirubinemic Patients.

BACKGROUND Activated partial thromboplastin time (aPTT) and antifactor Xa (anti-Xa) monitoring methods for unfractionated heparin (UFH) often disagree. The extent of discordance for those with elevated bilirubin remains unclear. Our objective was to evaluate concordance between activated aPTT and anti-Xa methods for hyperbilirubinemic patients on UFH. METHODS This was a retrospective cohort s...

متن کامل

Establishing the heparin therapeutic range using aPTT and anti-Xa measurements for monitoring unfractionated heparin therapy

BACKGROUND Unfractionated heparin (UFH) has unstable pharmacokinetics and requires close monitoring. The activated partial thromboplastin time (aPTT) test has been used to monitor UFH therapy for decades in Korea, but its results can be affected by numerous variables. We established an aPTT heparin therapeutic range (HTR) corresponding to therapeutic anti-Xa levels for continuous intravenous UF...

متن کامل

Use of a fixed activated partial thromboplastin time ratio to establish a therapeutic range for unfractionated heparin.

BACKGROUND The commonly recommended therapeutic range for patients receiving unfractionated heparin of 1.5 to 2.5 times the control activated partial thromboplastin time (aPTT) is not universally applicable. It has been suggested that the therapeutic range for each aPTT reagent should be based on plasma heparin levels. We sought to identify an aPTT ratio that corresponds to therapeutic anti--fa...

متن کامل

The PiCT® test is a reliable alternative to the activated partial thromboplastin time in unfractionated heparin therapy management: results from a multicenter study.

Essentials Activated partial thromboplastin time (APTT) or anti-Xa tests are used to monitor heparin. Prothrombinase-induced Clotting Time (PiCT) was compared to APTT in a clinical study. PiCT shows higher correlation to anti-Xa than APTT does and is more comparable between centers. PiCT demonstrates significantly higher accuracy and reliability than APTT in heparin monitoring. SUMMARY Backgr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JACC. Heart failure

دوره 3 4  شماره 

صفحات  -

تاریخ انتشار 2015