A Magnetic-Balanced Inductive Link for the Simultaneous Uplink Data and Power Telemetry

نویسندگان

  • Chen Gong
  • Dake Liu
  • Zhidong Miao
  • Min Li
چکیده

When using the conventional two-coil inductive link for the simultaneous wireless power and data transmissions in implantable biomedical sensor devices, the strong power carrier could overwhelm the uplink data signal and even saturate the external uplink receiver. To address this problem, we propose a new magnetic-balanced inductive link for our implantable glaucoma treatment device. In this inductive link, an extra coil is specially added for the uplink receiving. The strong power carrier interference is minimized to approach zero by balanced canceling of the magnetic field of the external power coil. The implant coil is shared by the wireless power harvesting and the uplink data transmitting. Two carriers (i.e., 2-MHz power carrier and 500-kHz uplink carrier) are used for the wireless power transmission and the uplink data transmission separately. In the experiments, the prototype of this link achieves as high as 65.72 dB improvement of the signal-to-interference ratio (SIR) compared with the conventional two-coil inductive link. Benefiting from the significant improvement of SIR, the implant transmitter costs only 0.2 mW of power carrying 50 kbps of binary phase shift keying data and gets a bit error rate of 1 × 10 - 7 , even though the coupling coefficient is as low as 0.005. At the same time, 5 mW is delivered to the load with maximum power transfer efficiency of 58.8%. This magnetic-balanced inductive link is useful for small-sized biomedical sensor devices, which require transmitting data and power simultaneously under ultra-weak coupling.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New System of Contactless Power Transfer with Low Voltage Stress and Parasitic Capacitors Effect

In this paper, a high frequency contactless power transfer (CPT) system is designed with ∅2 inverter drive. This system works in 30MHz frequency and 380W power with low voltage stress and considers the inductive link parasitic capacitor effect. In the design, we formulated the inverter equations first and then suggested another design for the transmitter and the receiver coils as the energy tra...

متن کامل

An NFC on Two-Coil WPT Link for Implantable Biomedical Sensors under Ultra-Weak Coupling

The inductive link is widely used in implantable biomedical sensor systems to achieve near-field communication (NFC) and wireless power transfer (WPT). However, it is tough to achieve reliable NFC on an inductive WPT link when the coupling coefficient is ultra-low (0.01 typically), since the NFC signal (especially for the uplink from the in-body part to the out-body part) could be too weak to b...

متن کامل

Characteristics of telemetry interference with pacemakers caused by digital media players.

BACKGROUND Contemporary implantable heart rhythm devices communicate multiple complex data simultaneously using radiofrequency telemetry. Interference in communication can expose them to the risk of potential corruption, leading to adverse clinical consequences. METHODS & RESULTS We studied the characteristics of interference with uplink (real time intracardiac electrograms, marker channel, a...

متن کامل

Towards high-resolution retinal prostheses with direct optical addressing and inductive telemetry.

OBJECTIVE Despite considerable advances in retinal prostheses over the last two decades, the resolution of restored vision has remained severely limited, well below the 20/200 acuity threshold of blindness. Towards drastic improvements in spatial resolution, we present a scalable architecture for retinal prostheses in which each stimulation electrode is directly activated by incident light and ...

متن کامل

BER Performance of a BPSK Biomedical Telemetry System under Varying Coupling and Loading Conditions

Binary Phase Shift Keying (BPSK) is a promising modulation format for downlink data transmission in inductive biomedical telemetry systems, because it achieves high data rates and power efficiencies and requires simple electronics. In this paper, the Bit Error Rate (BER) performance of a BPSK biomedical telemetry system is investigated under Additive White Gaussian Noise (AWGN) and is found to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2017