Plate osteosynthesis of simple forearm fractures: LCP versus DC plates.

نویسندگان

  • Charles Tjerk Stevens
  • Henk Jan ten Duis
چکیده

The aim of this study was to compare the time to radiological bony union of simple A-type fractures of the forearm, treated with either a locking compression plate (LCP) or a dynamic compression plate (DCP). For each fracture, the relation between the use of compression and radiological healing time was studied. Nine fractures were treated with LCP and 10 fractures with DC plates. The mean time to definite radiological bony union in the LCP group was 33 weeks and in the DCP group 22 weeks. Compression was used in 7 fractures in the DCP group and in 3 fractures in the LCP group. The compressed fractures, irrespective of the type of plate, healed 10 weeks faster than the non-compressed fractures. Time to definite radiological bony union of simple A-type fractures does not depend on the type of plate used, but on the application of axial or interfragmentary compression.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment of type 2 and 4 olecranon fractures with locking compression plate osteosynthesis in horses: a prospective study (2002-2008).

This prospective study describes a series of 18 olecranon fractures in 16 horses that were treated with locking compression plates (LCP). Twelve of the 18 fractures were simple (type 2), whereas six were comminuted (type 4). Six fractures were open and 12 were closed. Each horse underwent LCP osteosynthesis consisting of open reduction and application of one or two LCP. Complete fracture healin...

متن کامل

Effectiveness of locking versus dynamic compression plates for diaphyseal forearm fractures.

This study compares the results of the locking compression plate (LCP) and the dynamic compression plate (DCP) in the treatment of diaphyseal forearm fractures in adults and defines the indications for the use of the LCP. Forty-two patients with diaphyseal forearm fractures were retrospectively analyzed. Of those, 22 had been treated with the LCP (LCP group) and 20 had been treated with the DCP...

متن کامل

Comparing the In Vitro Stiffness of Straight-DCP, Wave-DCP, and LCP Bone Plates for Femoral Osteosynthesis

The objective of this study was to compare the Locking Compression Plate (LCP) with the more cost-effective straight-dynamic compression plate (DCP) and wave-DCPs by testing in vitro the effects of plate stiffness on different types of diaphyseal femur fractures (A, B, and C, according to AO classification). The bending structural stiffness of each plate was obtained from four-point bending tes...

متن کامل

Zásady a klinické použití uzamykatelné kompresní dlahy LCP

The principle of the locking compression plate (LCP) is represented by the combination of two completely different anchorage technologies and two opposed principles of osteosynthesis in one implant it combines the principles of conventional plate osteosynthesis for direct anatomical reduction with those of bridging plate osteosynthesis. Since the LCP can be used as a conventional plate using on...

متن کامل

Dynamic plate osteosynthesis for fracture stabilization: how to do it

Plate osteosynthesis is one treatment option for the stabilization of long bones. It is widely accepted to achieve bone healing with a dynamic and biological fixation where the perfusion of the bone is left intact and micromotion at the fracture gap is allowed. The indications for a dynamic plate osteosynthesis include distal tibial and femoral fractures, some midshaft fractures, and adolescent...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta orthopaedica Belgica

دوره 74 2  شماره 

صفحات  -

تاریخ انتشار 2008