Transvenous Closure of Patent Foramen Ovale: Preliminary Results with a New Self-Expanding Nitinol Wire Mesh in a Swine Model
نویسندگان
چکیده
Objectives. The transvascular closure of patent foramen ovale (PFO) with self-expanding devices carries the risk of left atrial thrombus formation related to material protruding into the left atrium. Thus, we developed a novel device with flat left atrial disc geometry. We evaluated feasibility, handling, and biocompatibility in a porcine animal model. Methods. Implantation of an Occlutech Figulla PFO device was performed in 10 mini pigs using fluoroscopy and intra-cardiac ultrasound after transseptal puncture of the interatrial septum. Angiographic follow-up was performed after six and twelve weeks. Results. Implantation was successful in 100%. There were no further implant related complications. One procedure related death occurred, as one animal died of ventricular tachycardia due to mispunture of the interatrial septum. Angiographic studies showed no residual shunt during follow-up. Histopathological evaluation could demonstrate partial neoendothelialization after 6 weeks with completion after 12 weeks. The devices were incorporated into connective tissue containing fibro muscular cells. An only mild inflammatory reaction was detected locally related to the polyester fibers. Conclusion. In terms of feasibility and handling, the new device does not seem to be inferior to other presently used implantation systems. Good biocompatibility was demonstrated with rapid and complete neoendothelialization.
منابع مشابه
Application of Cardio-O-Fix occluders for transcatheter closure of patent ductus arteriosus and interatrial communications: Preliminary experience.
BACKGROUND Transcatheter treatment has become the method of choice for treating many heart defects. Recently, Cardio-O-Fix occluder (COF) - a new, self-expandable nitinol wire-mesh device very similar to the Amplatzer device - has been introduced into clinical practice. To the best of our knowledge, this is the first publication related to its application. METHODS Five patients aged from six ...
متن کاملHeart Carcinoid Disease with Patent Foramen Ovale Treated by Mini Sternotomy
This case report was an attempt to present the importance of diagnostic echocardiography and closure of a patent foramen ovale in carcinoid heart disease. Herein, we present a case of a 48-year-old woman with a carcinoid metastasis presenting with tricuspid regurgitation, pulmonic stenosis, patent foramen ovale, and borderline left ventricular ejection fraction on an echocardiogram. Surgical in...
متن کاملTranscatheter closure of patent foramen ovale using the Amplatzer septal occluder to prevent recurrence of neurological decompression illness in divers.
OBJECTIVE Large flap valve patent foramens may cause paradoxical thromboembolism and neurological decompression illness in divers. The ability of a self expanding Nitinol wire mesh device (Amplatzer septal occluder) to produce complete closure of the patent foramen ovale was assessed. PATIENTS Seven adults, aged 18-60 years, who had experienced neurological decompression illness related to di...
متن کاملPercutaneous steerable robotic tool delivery platform and metal microelectromechanical systems device for tissue manipulation and approximation: closure of patent foramen ovale in an animal model.
BACKGROUND Beating-heart image-guided intracardiac interventions have been evolving rapidly. To extend the domain of catheter-based and transcardiac interventions into reconstructive surgery, a new robotic tool delivery platform and a tissue approximation device have been developed. Initial results using these tools to perform patent foramen ovale closure are described. METHODS AND RESULTS A ...
متن کاملTranscatheter closure of patent foramen ovale using the internal jugular venous approach
Transcatheter closure of patent foramen ovale is routinely performed using the transfemoral approach, which is safe and technically easy. Our case represents the rare situation where the procedure needs to be performed using the right internal jugular venous approach. According to our best knowledge this is the first report of a patent foramen ovale closure procedure with access through the int...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2009 شماره
صفحات -
تاریخ انتشار 2009