Dosimetric impact of the 160 MLC on head and neck IMRT treatments
نویسندگان
چکیده
The purpose of this work is to investigate if the change in plan quality with the finer leaf resolution and lower leakage of the 160 MLC would be dosimetrically significant for head and neck intensity-modulated radiation therapy (IMRT) treat- ment plans. The 160 MLC consisting of 80 leaves of 0.5 cm on each bank, a leaf span of 20 cm, and leakage of less than 0.37% without additional backup jaws was compared against the 120 Millennium MLC with 60 leaves of 0.5 and 1.0 cm, a leaf span of 14.5 cm, and leakage of 2.0%. CT image sets of 16 patients previously treated for stage III and IV head and neck carcinomas were replanned on Prowess 5.0 and Eclipse 11.0 using the 160 MLC and the 120 MLC. IMRT constraints for both sets of 6 MV plans were identical and based on RTOG 0522. Dose-volume histograms (DVHs), minimum dose, mean dose, maximum dose, and dose to 1 cc to the organ at risks (OAR) and the planning target volume, as recommended by QUANTEC 2010, were compared. Both collimators were able to achieve the target dose to the PTVs. The dose to the organs at risk (brainstem, spinal cord, parotids, and larynx) were 1%-12% (i.e., 0.5-8 Gy for a 70 Gy prescription) lower with the 160 MLC compared to the 120 MLC, depending on the proximity of the organ to the target. The large field HN plans generated with the 160 MLC were dosimetrically advantageous for critical structures, especially those located further away from the central axis, without compromising the target volume.
منابع مشابه
The Dosimetric Effects of Different Multileaf Collimator Widths on Physical Dose Distributions
Introduction: Geometric changes in the multileaf collimator (MLC) led to dosimetric considerations in intensity-modulated radiation therapy (IMRT) due to the number and size of the pixels in the intensity map, which are determined by the MLC leaf width. In this study, we evaluated the dosimetric effects of different MLC widths on physical dose distributions for IMRT plans. Materials and Method...
متن کاملInvestigation of physical penumbra definition in IMRT applications
Introduction: Because of small size of the beamlets in IMRT, physical penumbra is one of the important dosimetric parameters and small changes in the penumbra will have a great impact on the results. The physical penumbra width is defined as the lateral distance between two specified isodose curves at a specified depth of phantom. In this study, after demonstrating the inconsi...
متن کاملDevelopment of an optimum photon beam model for head‐and‐neck intensity‐modulated radiotherapy
Intensity-modulated radiotherapy (IMRT) for complex sites such as tumors of the head and neck requires a level of accuracy in dose calculation beyond that currently used for conformal treatment planning. Recent advances in treatment planning systems have aimed to improve the dose calculation accuracy by improving the modeling of machine characteristics such as interleaf leakage, tongue and groo...
متن کاملThe effect of high energy photon beam in dose- volume parameters and integral dose of normal structures in Head and neck IMRT
Introduction: The aim of this study is to investigate the effect of partially used high photon energies on dosimetric parameters and integral doses of nasopharynx IMRT plans. Materials and Methods: Two 7 coplanar IMRT plan were created for eleven patients (6 MV only IMRT plan in both phase1 and phase2 and 6 MV phase1-mixed energies (6 MV and 15 MV) phase2...
متن کاملImpact of MLC properties and IMRT technique in meningioma and head-and-neck treatments
PURPOSE The impact of multileaf collimator (MLC) design and IMRT technique on plan quality and delivery improvements for head-and-neck and meningioma patients is compared in a planning study. MATERIAL AND METHODS Ten previously treated patients (5 head-and-neck, 5 meningioma) were re-planned for step-and-shoot IMRT (ssIMRT), sliding window IMRT (dMLC) and VMAT using the MLCi2 without (-) and ...
متن کامل