Image Warping for Accurate Digital Subtraction Angiography

نویسندگان

  • Rajiv Gupta
  • Chukka Srinivas
چکیده

This paper describes a system for sub-pixel registration of mask and opacified digital X-ray images so that the mask image can be accurately subtracted out from the opacified image. Our technique results in digital subtraction angiograms (DSAs) with fewer artifacts and better contrast.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nonrigid Image Registration in Digital Subtraction Angiography Using Multilevel B-Spline

We address the problem of motion artifact reduction in digital subtraction angiography (DSA) using image registration techniques. Most of registration algorithms proposed for application in DSA, have been designed for peripheral and cerebral angiography images in which we mainly deal with global rigid motions. These algorithms did not yield good results when applied to coronary angiography imag...

متن کامل

A Fast Image Registration Technique for Motion Artifact Reduction in DSA

In digital subtraction angiography (DSA), patient motion is the primary cause of image quality degradation. The motion correction algorithms developed so far were not sufficiently fast so as to be suitable for integration in a clinical setting. In this paper we describe a new image registration technique for motion artifact reduction in DSA which is fully automatic, effective, and computational...

متن کامل

Motion compensated digital subtraction angiography

Digital subtraction angiography, whether based on traditional X-ray or MR, su ers from patient motion artifacts. Until now, the usual remedy is to pixel shift by hand, or in some cases performing a global pixel shift semi-automatically. This is time consuming, and cannot handle rotations or local varying deformations over the image. We have developed a fully automatic algorithm that provides fo...

متن کامل

MR Digital Subtraction Angiography

Analysis of Subtraction Methods in 3D Contrast-Enhanced MR Digital Subtraction Angiography Yuexi Huang Master of Science 2001 Department of Medical Biophysics University of Toronto 3D Contrast-enhanced MR angiography is promising as a replacement to catheter-based x-ray angiography due to its non-invasive nature. However, the image quality of MR angiography is still inferior to that of x-ray an...

متن کامل

Digital subtraction CT angiography based on efficient 3D registration and refinement.

A novel method for fast, automatic 3D digital subtraction CT angiography (DS-CTA) is presented to generate artifact-free angiograms. The proposed method consists of two steps: 3D registration to align a CT image to the CT angiography (CTA) image and subtraction-and-refinement to extract blood vessels only. For efficient and accurate 3D registration in the first step, an normalized mutual inform...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002