Influence of the pinhole size on the resolution of the 4Pi’ microscope studied by means of the optical transfer function

نویسندگان

  • N. Sandeau
  • H. Giovannini
  • Nicolas Sandeau
  • Hugues Giovannini
چکیده

Optical transfer functions are presented for the 4pi’ microscope. The effects of the size of the confocal pinhole on the threedimensional resolution are studied. It is shown that the resolution of the 4Pi’ microscope depends weakly on the pinhole size. This result suggest that the pinhole can be removed in order to increase the signal-to-noise ratio. PACS: 42.30.Lr; 42.30.-d; 87.64.Rr

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cooperative 4Pi excitation and detection yields sevenfold sharper optical sections in live-cell microscopy.

Although the addition of just the excitation light field at the focus, or of just the fluorescence field at the detector is sufficient for a three- to fivefold resolution increase in 4Pi-fluorescence microscopy, substantial improvements of its optical properties are achieved by exploiting both effects simultaneously. They encompass not only an additional expansion of the optical bandwidth, but ...

متن کامل

Increasing the Lateral Resolution in Confocal Fluorescence and Bio-luminescence Microscopes

Improving the spatial resolution in optical microscopes is a challenging task for many applications. In fluorescence confocal microscopy, the resolution is given by the Detection Efficiency Function (DEF) resulting from the product of the Excitation Efficiency Function (EEF) by the Collection Efficiency Function (CEF). The focalisation of the pump laser beam by a high numerical aperture objecti...

متن کامل

پایدار‌سازی ساختار تتراگونال زیر‌کونیا در سرمتهای لایه نازکZr-O و وابستگی آن به اندازه بلورکها

 In this research, thin films of Zr/ZrO2 composites were deposited by reactive magnetron sputtering technique on Si and fused Silica substrates, and their structures were investigated by XRD method. During the deposition of the cermet layers, a Zr metallic target was sputtered in a gas mixture of Ar and O2. By controlling of O2 flow rate, the different metal volume fractions in the cermet layer...

متن کامل

Optical transfer functions of 4Pi confocal microscopes: theory and experiment.

We measure the point-spread function in the two main configurations of 4Pi confocal microscopy as well as in the traditional confocal arrangement and derive the optical transfer functions from the experimental data. The optical transfer functions are in good agreement with their theoretical counterparts. We find a 3.5- to 5-fold increased axial bandwidth of the 4Pi confocal microscope and hence...

متن کامل

Influence of optical Kerr coefficient on photonic band structures of hexagonal-lattice function photonic crystals

In this paper, we have studied the photonic band structure of function photonic crystals in which the dielectric constant of the scattering centers (rods) is a function of space coordinates. The under-studied lattice is hexagonal and cross section of rods has a circular symmetry embedded in the air background. Photonic band structures for both electric and magnetic polarizations of the electrom...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017