Microbubbles shunting via a patent foramen ovale impair endothelial function
نویسندگان
چکیده
OBJECTIVES Exposure to intravascular microbubbles after diving and during medical procedures alters endothelial function. The aim of this study was to investigate whether a patent foramen ovale altered forearm endothelial function by facilitating microbubbles transfer. DESIGN Patients attended on two separate visits, at least seven days apart receiving agitated saline or no active intervention in random order. On both days, flow-mediated dilatation of the brachial artery was measured using vascular ultrasound. On the intervention visit, agitated saline was injected and the passage of microbubbles into the arterial circulation was confirmed by echocardiography. Serial flow-mediated dilatation measurements were made after agitated saline and at the same time points after no intervention. SETTING St Thomas' Hospital in London. PARTICIPANTS Patients with a patent foramen ovale (PFO+n = 14, 9 male, mean ± SD age 42.2 ± 10.5 years) and patients without a patent foramen ovale (PFO- n = 10, 7 male, mean ± SD age 49.4 ± 18.4 years) were recruited. MAIN OUTCOME MEASURES Change in brachial artery flow-mediated dilatation. RESULTS In patent foramen ovale + patients, flow-mediated dilatation did not change significantly on the control day but after agitated saline reduced by 2.3 ± 0.3%, 20 minutes after bubble injection (P < 0.005 vs. corresponding change in flow-mediated dilatation during control study). There was no significant change in flow-mediated dilatation for patent foramen ovale- patients at either visit. CONCLUSION These results suggest that the presence of a patent foramen ovale facilitated impairment of endothelial function acutely by the transfer of microbubbles into the arterial circulation. As a patent foramen ovale is a common condition, this may be relevant to microbubbles exposure in medical procedures and in decompression illness.
منابع مشابه
Characteristics of patent foramen ovale associated with cryptogenic stroke. A biplane transesophageal echocardiographic study.
BACKGROUND AND PURPOSE Patent foramen ovale is associated with ischemic stroke in patients without a clearly identifiable etiology for stroke (cryptogenic stroke). Paradoxical embolization is thought to be a potential mechanism. However, patent foramen ovale is also found in patients with known cause of stroke. Therefore, using contrast transesophageal echocardiography, we characterized the pat...
متن کاملHeart Carcinoid Disease with Patent Foramen Ovale Treated by Mini Sternotomy
This case report was an attempt to present the importance of diagnostic echocardiography and closure of a patent foramen ovale in carcinoid heart disease. Herein, we present a case of a 48-year-old woman with a carcinoid metastasis presenting with tricuspid regurgitation, pulmonic stenosis, patent foramen ovale, and borderline left ventricular ejection fraction on an echocardiogram. Surgical in...
متن کاملUse of the transseptal puncture in transcatheter closure of long tunnel-type patent foramen ovale.
Two patients with long tunnel-type patent foramen ovale presented for elective transcatheter closure following transient ischaemic attack and stroke. Right to left shunting was confirmed on transthoracic and transoesophageal echocardiography. A new technique that used a transseptal procedure was devised to enable closure of the tunnel-type patent foramen ovale using the CardioSEAL transseptal o...
متن کاملProvoked right-to-left shunt in patent foramen ovale associates with ischemic stroke in posterior circulation.
BACKGROUND AND PURPOSE Right-to-left shunt (RLS) via the patent foramen ovale is an important cause of cryptogenic stroke. The Valsalva maneuver provokes or enhances RLS, but RLS can also occur during normal respiration. This study examined whether the ischemic lesion pattern differs depending on the character of RLS. METHODS All consecutive patients with a patent foramen ovale (diagnosed by ...
متن کاملUnusual treatment of patent foramen ovale after pneumonectomy.
This manuscript will focus on a rare complication: shunting through a patent foramen ovale (PFO) as a long term complication of right sided pneumonectomy or bilobectomy. Three patients who were diagnosed with shunting through a patent foramen ovale following lung resection are described. In these patients right ventricular compression by the elevated right hemidiaphragm was the cause of shuntin...
متن کامل