Performance Analysis of BUNSD-LMA
نویسندگان
چکیده
The IETF is developed Network Mobility Basic Support (NEMO BSP) to support session continuity and reachability to the Mobile Network Nodes (MNNs) as one unit while they move. While NEMO move and attached to different networks, it needs to register the MNNs. This function of registration decreases the performance of NEMO. NEMO BSP suffers from some challenges. The most important of these challenges are route optimization, seamless mobility, handover latency and registration time. Binding Update No Sense Drop (BUNSD) Binding Cache Entry (BCE) in Local Mobility Anchor (LMA) is proposed to find a possible solution to MNNs. MNNs that are roaming in a Proxy Mobile IPv6 (PMIPv6) domain to perform seamless mobility while they are maintaining their session continuity through mobile router (MR). In this paper, BUNSD-LMA is analyzed mathematically with NEMO BS based on handover latency, total packet delivery delay cost, and throughput time during handoff. The analytical result shows that the BUNSD-LMA had better performance in term of handover, and registrations of MNNs. As a result the total packet loss is decreased and seamless mobility of MNNs enhanced compared to NEMO BS benchmarks.
منابع مشابه
Comparison of oropharyngeal leak pressure and clinical performance of LMA ProSeal™ and i-gel® in adults: Meta-analysis and systematic review
BACKGROUND A meta-analysis and systematic review of randomized controlled trials to compare the oropharyngeal leak pressure (OLP) and clinical performance of LMA ProSeal™ (Teleflex® Inc., Wayne, PA, USA) and i-gel® (Intersurgical Ltd, Wokingham, UK) in adults undergoing general anesthesia. METHODS Searches of MEDLINE®, EMBASE®, CENTRAL, KoreaMed and Google Scholar® were performed. The primary...
متن کاملPerformance Analysis Of IPMSM Drive Using Fuzzy Logic Controller Based Loss Minimization Algorithm (LMA)
This project presents an online lossminimization algorithm (LMA) for a fuzzy-logiccontroller (FLC)-based interior permanent-magnet synchronous-motor (IPMSM) drive to yield high efficiency and high dynamic performance over a wide speed range. LMA is developed based on the motor model. In order to minimize the controllable electrical losses of the motor and thereby maximize the operating efficien...
متن کاملCOMPARISON BETWEEN THE EFFICACY OF TRAPEZIUS SQUEEZING TEST AND JAW THRUST MANEUVER FOR PREDICTION OF SUCCESSFUL INSERTION OF LARYNGEAL MASK AIRWAY
Background & Aims: The aim of this study was to compare trapezius squeezing and jaw thrust to evaluate suitable conditions for laryngeal mask airway (LMA) insertion. Materials & Methods: In this clinical trial study, 138 patients with ASA physical status 1 or 2 who were candidates for elective surgery of shin fracture were randomly assigned into one of the groups of trapezius squeeze and raisi...
متن کاملLimitation of Laryngeal Mask Airway Usage in Open-Neck Procedure
I read the manuscript entitled “Case Report of An Open Neck Procedure Complication Associated with Laryngeal Mask Airway Use” by Subramaniam T et al. This is a valuable manuscript describing iatrogenic complications during level-2 cervical lymph node biopsy, in which the airway is managed with laryngeal mask airway (LMA). During the procedure, the surgeon realized that the mass was actually the...
متن کاملمقایسه نتایج بهکارگیری دو روش جدید و کلاسیک جایگذاری ماسک حنجرهای
Background and Aim: The laryngeal mask airway (LMA) maintains the airway under anesthesia through spontaneous breathing technique without the need of endotracheal intubations. Although routine LMA supports an adequate tracheal airway, the classic method had some limitations and problems. In this study, we compared the results of the two methods of (new and classic) LMA. Patients and Meth...
متن کامل