چکیده

This paper reports the development of optical lever based parylene cantilevers for biochemical sensing. A simple but effective process to fabricate parylene cantilevers using Tetramethylammonium Hydroxide (TMAH) bulkmicromachining was demonstrated. A scheme of using anchoring holes was employed to prevent the peeling off of parylene during TMAH etching. Moreover, ridge structures were incorporated on the cantilever tip to achieve a flat surface for a well-controlled reflected laser spot. An analytical model was presented to guide the design of the cantilever sensor. The stability of the parylene cantilever sensor in water and buffer solution was demonstrated. Based on optical lever method, the parylene cantilevers successfully detected vapour phase alkanethiols, and DNA molecules in buffer solution.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of cantilever geometry on the optical lever sensitivities and thermal noise method of the atomic force microscope.

Calibration of the optical lever sensitivities of atomic force microscope (AFM) cantilevers is especially important for determining the force in AFM measurements. These sensitivities depend critically on the cantilever mode used and are known to differ for static and dynamic measurements. Here, we calculate the ratio of the dynamic and static sensitivities for several common AFM cantilevers, wh...

متن کامل

Noninvasive determination of optical lever sensitivity in atomic force microscopy

Atomic force microscopes typically require knowledge of the cantilever spring constant and optical lever sensitivity in order to accurately determine the force from the cantilever deflection. In this study, we investigate a technique to calibrate the optical lever sensitivity of rectangular cantilevers that does not require contact to be made with a surface. This noncontact approach utilizes th...

متن کامل

Calibration of frictional forces in atomic force microscopy

The atomic force microscope can provide information on the atomic-level frictional properties of surfaces, but reproducible quantitative measurements are difficult to obtain. Parameters that are either unknown or difficult to precisely measure include the normal and lateral cantilever force constants (particularly with microfabricated cantilevers), the tip height, the deflection sensor response...

متن کامل

The influence of refractive index change and initial bending of cantilevers on the optical lever readout method.

It has been speculated that the initial bending of cantilevers has a major influence on the detector signal in a cantilever-based sensor using the optical lever readout method. We have investigated theoretically as well as experimentally the changes induced in the detector signal when the optical lever technique is used to monitor a cantilever with initial bending during changes in the refracti...

متن کامل

Mechanical and thermal effects of laser irradiation on force microscope cantilevers

In an optical lever set-up one or two modulated laser beams of 0,1 to 6 mW modulation amplitude at a wavelength of 670 nm were focused at uncoated and gold-coated microfabricated cantilevers. The motion of the levers was analyzed by an optical lever set-up. The mechanical resonance (30 to 60 kHz) of the cantilevers was excited by the modulated light both in air and under vacuum conditions (10 6...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008