The Measurement of Opening Angle and Orifice Area of a Bileaflet Mechanical Valve Using Multidetector Computed Tomography

نویسندگان

  • Dong-Hyeon Lee
  • Ho-Joong Youn
  • Sung-Bo Shim
  • Sun-Hee Lee
  • Jung-Im Jung
  • Seung-Eun Jung
  • Yun-Seok Choi
  • Chul-Soo Park
  • Yong-Seog Oh
  • Wook-Sung Chung
  • Jae-Hyung Kim
چکیده

BACKGROUND AND OBJECTIVES The aim of this study was to assess mechanical valve function using 64-slice multidetector computed tomography (MDCT). SUBJECTS AND METHODS In 20 patients (mean age, 50+/-12 years; male-to-female ratio, 10:10), 30 St. Jude bileaflet mechanical valves (15 aortic and 15 mitral valves) were evaluated using MDCT. We selected images vertical and parallel to the mechanical valve. The valve orifice area (OA) and valve length were determined by manual tracing and the opening and closing angles were measured using a protractor. The OA and length of the mechanical valves were compared with the manufacturer's values. RESULTS The geometric orifice areas (GOAs) based on the manufacturer's values and the OAs determined by MDCT were 3.4+/-0.2 cm(2) and 3.4+/-0.3 cm(2) for the mitral valves and 2.1+/-0.3 cm(2) and 2.1+/-0.4 cm(2) for the aortic valves, respectively. The correlation coefficients between the OA measures were 0.433 for the mitral valves and 0.874 for the aortic valves (both p<0.001). The lengths based on the manufacturer's values and determined by MDCT were 29.3+/-1.99 mm and 29.6+/-1.65 mm for the mitral valves and 21.5+/-2.1 mm and 20.7+/-2.3 mm for the aortic valves, respectively. The correlation coefficients between the measures were 0.651 for the mitral valve and 0.846 for the aortic valve (both p<0.001). The opening and closing angles determined by MDCT were 10.9+/-0.6 degrees and 131.1+/-3.2 degrees for the mitral valves and 11.1+/-0.9 degrees and 120.6+/-1.7 degrees for the aortic valves, respectively. CONCLUSION MDCT is an accurate modality with which to assess the function and morphology of bileaflet mechanical valves.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hemodynamic and functional assessment of mechanical aortic valves using combined echocardiography and multidetector computed tomography.

BACKGROUND Limitations are found in the ability of transthoracic echocardiography to evaluate mechanical aortic valve replacements (AVR). We evaluated the ability of combined echocardiography and computed tomography (CT) to enhance the hemodynamic and functional evaluation of AVR. METHODS We performed a retrospective evaluation of 41 consecutive patients with AVR (27 bileaflet, 14 single disc...

متن کامل

Evaluation of prosthetic valve obstruction on electrocardiographically gated multidetector-row computed tomography--identification of subprosthetic pannus in the aortic position.

BACKGROUND This study was performed to evaluate the diagnostic role of electrocardiographically gated multidetector-row computed tomography (MDCT) for prosthetic valve obstruction (PVO) in the aortic position. METHODS AND RESULTS Between 2002 and 2006, 9 patients were diagnosed with PVO of an aortic bileaflet mechanical valve based on echocardiographic and cineradiographic criteria. These 9 p...

متن کامل

Three-dimensional reconstruction of New Zealand rabbit antebrachium by multidetector computed tomography

The aim of this study was to reveal biometric peculiarities of New Zealand white rabbit antebrachium (radius and ulna) by means of three-dimensional (3D) reconstruction of multidetector computed tomography (MDCT) images. Under general anesthesia, the antebrachiums of a total of sixteen rabbits of both sexes were scanned with a general diagnostic MDCT. Biometric measurements of the reconstructed...

متن کامل

A method for determining the reference effective flow areas for mechanical heart valve prostheses: in vitro validation studies.

BACKGROUND The anatomic opening area (AOA) is usually reported as the primary index of mechanical heart valve function. Because flow contracts immediately distal to an orifice as a result of the vena contracta effect, AOA may not be a good measure of true effective flow area. METHODS AND RESULTS Laser flow imaging was used to visualize the contraction in the jet flow stream as it passed throu...

متن کامل

Predicting ATS Open Pivot heart valve performance with computational fluid dynamics.

BACKGROUND AND AIM OF THE STUDY In-vitro studies on the ATS heart valve have indicated that valve opening is less in an expanding conduit than in a straight conduit. METHODS Bileaflet valve behavior was studied using a new computational fluid-structure interaction model. A three-dimensional model of the ATS valve was studied in two geometries, simulating the valve in a geometry with sudden ex...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 39  شماره 

صفحات  -

تاریخ انتشار 2009