Experimental assessment of PET/CT repeatability
نویسندگان
چکیده
Purpose: In longitudinal oncological and brain PET/CT studies it is important to understand the repeatability of quantitative PET metrics in order to assess change in tracer uptake or binding. The present studies were performed in order to assess the aspects of PET/CT repeatability related to reconstruction settings, analysis methods, scan duration (or image noise) and position in the field of view. Procedures: Multiple (repeated) scans have been performed using a uniform Ge phantom, a NEMA image quality (IQ) phantom and a 3D Hoffman brain phantom filled with F solutions. Studies were performed with and without repositioning the phantom and all (12 replicate for IQ phantom and 10 replicate for Hoffman brain phantom) scans were performed using equal count statistics. For the Ge phantom, the coefficient of variation (COV%) and variance of the voxel values across the phantom were studied as function of scan statistics and reconstruction settings. For the NEMA IQ phantom we studied the maximum, peak and mean recovery coefficients (RC) in each sphere as function of experimental conditions (noise level, reconstruction settings and phantom repositioning). For the 3D Hoffman phantom the mean activity concentration was determined within several volumes of interest and activity recovery and its precision was studied as function of experimental conditions. Results: For all phantom studies voxel noise (expressed by variance and COV) and SUVmax or SUVmean repeatability depended on reconstruction settings and frame duration, as expected. When exploring SUVmax, SUVpeak or SUVmean of the spheres in the NEMA IQ phantom, it was observed that repeatability depended on phantom position with SUVmax being most and SUVpeak least sensitive to phantom repositioning. Moreover, the impact of phantom positioning on SUV metrics depended on sphere size. For the brain phantom, regional average SUVs were derived and these were only minimally affected by phantom repositioning. Conclusion: The repeatability of quantitative PET metrics depends on the combination of reconstruction settings, data analysis methods and scan duration (scan statistics). Moreover, repeatability was also affected by phantom repositioning but its impact depended largely on the data analysis method being used. The study suggest that for oncological PET studies use of SUVpeak may be preferred over SUVmax because SUVpeak metric is likely less sensitive to patient positioning/tumor sampling effects.
منابع مشابه
Repeatability of quantitative FDG-PET/CT and contrast-enhanced CT in recurrent ovarian carcinoma: test-retest measurements for tumor FDG uptake, diameter, and volume.
PURPOSE Repeatability of baseline FDG-PET/CT measurements has not been tested in ovarian cancer. This dual-center, prospective study assessed variation in tumor 2[18F]fluoro-2-deoxy-D-glucose (FDG) uptake, tumor diameter, and tumor volume from sequential FDG-PET/CT and contrast-enhanced computed tomography (CECT) in patients with recurrent platinum-sensitive ovarian cancer. EXPERIMENTAL DESIG...
متن کاملReliability of PET/CT shape and heterogeneity features in functional and morphological components of Non-Small Cell Lung Cancer tumors: a repeatability analysis in a prospective multi-center cohort
The main purpose of this study was to assess the reliability of shape and heterogeneity features in both the PET and the low-dose CT components of PET/CT. A secondary objective was to investigate the impact of image quantization. Methods: A Health Insurance Portability and Accountability Act-compliant secondary analysis of deidentified prospectively acquired PET/CT test-retest datasets of 74 pa...
متن کامل18F-FDG PET/CT usefulness vs Tc99m-Tetrofosmin in the assessment of malignant brain gliomas: Report of two cases
Gliomas account for almost 80% of primary malignant brain tumors in adults. Magnetic Resonance imaging (MRI) is still the gold standard for diagnosis of brain tumors and brain 99mTc-tetrofosmin Single Photon Emission Computed Tomography (99mTc-tetrofosmin-SPECT) has been established as a useful tool for their evaluation. Fluorine-18–2-fluoro-2-deoxy-d-glucose positron emi...
متن کاملRepeatability of Standardized Uptake Value in Oncologic 18F-FDG PET
Quantitative analysis can potentially improve the accuracy and consistency of 2-18F-fluoro-2deoxy-D-glucose (18F-FDG) positron emission tomography (PET), particularly for the assessment of tumor response to treatment. Although not without limitations, standardized uptake value (SUV) has emerged as the predominant metric for tumor quantification with 18F-FDG PET. Growing literature suggests that...
متن کاملDetection of extra-cardiac hypermetabolic foci by [18F]FDG PET/CT in case of infective endocarditis and post antibiotic therapy response assessment
The diagnosis of prosthetic valve endocarditis continues to present a diagnostic challenge, due to the lower sensitivity of the modified Duke criteria and a higher percentage of negative or inconclusive echocardiography results. Diagnostic delay might result in significant morbidity/mortality. Imaging modalities like 2-[18F]fluoro-2-deoxy-D-glucose positron emission tomography/comput...
متن کامل