Comparison of conforming and nonconforming retrieved glenoid components.
نویسندگان
چکیده
The purpose of this study was to compare differences in wear performance of conforming and nonconforming glenoid designs, using clinical, radiographic, and retrieved polyethylene glenoid component outcome Sixty-three glenoids met the study criteria, and each glenoid was assigned to the conforming group (if the radii of curvature of the humeral and glenoid components were identical) or the nonconforming group (if a mismatch existed between the radii of curvature). The mean length of implantation was 5.6 +/- 5.5 years in the conforming group and 3.1 +/- 3.1 years for the nonconforming group (P < .05). The loosening score was 3.2 +/- 2.0 in the conforming group and 2.4 +/- 1.2 in the nonconforming one (P < .05). The nonconforming group had a significantly greater burnishing score (P < .01), while the conforming group had greater abrasion and delamination scores (P < .05). Articular conformity contributes to differences observed from retrieved polyethylene glenoid components, which are consistent with differences in performance that may influence loosening.
منابع مشابه
Biomechanical evaluation of a novel glenoid design in total shoulder arthroplasty.
The amount of articular curvature mismatch providing optimal performance in total shoulder arthroplasty (TSA) is unknown. The objectives of this study were to quantify glenohumeral joint mechanics before and after TSA and to compare the performance of 3 glenoid components: (1) nonconforming, (2) conforming, and (3) a novel design featuring a conforming center extending into a nonconforming peri...
متن کاملA New Acceptance Sampling Plan Based on Cumulative Sums of Conforming Run-Lengths
In this article, a novel acceptance-sampling plan is proposed to decide whether to accept or reject a receiving batch of items. In this plan, the items in the receiving batch are inspected until a nonconforming item is found. When the sum of two consecutive values of the number of conforming items between two successive nonconforming items falls underneath of a lower control threshold, the batc...
متن کاملA 3d Conforming-nonconforming Mixed Finite Element for Solving Symmetric Stress Stokes Equations
We propose a 3D conforming-nonconforming mixed finite element for solving symmetric stress Stokes equations. The low-order conforming finite elements are not inf-sup stable. The low-order nonconforming finite elements do not satisfy the Korn inequality. The proposed finite element space consists of two conforming components and one nonconforming component. We prove that the discrete inf-sup con...
متن کاملInf-sup Stable Nonconforming Finite Elements of Higher Order on Quadrilaterals and Hexahedra
Abstract. We present families of scalar nonconforming finite elements of arbitrary order r ≥ 1 with optimal approximation properties on quadrilaterals and hexahedra. Their vector-valued versions together with a discontinuous pressure approximation of order r − 1 form inf-sup stable finite element pairs of order r for the Stokes problem. The well-known elements by Rannacher and Turek are recover...
متن کاملObservations on retrieved glenoid components from total shoulder arthroplasty.
HYPOTHESIS Polyethylene components retrieved at revision of total knee and hip replacements have been analyzed to study the effect of design, patient, and surgical factors on initial implant performance, but few studies have reported similar types of findings in retrieved glenoids. MATERIALS AND METHODS From 1979 to 2006, 78 glenoid components were retrieved from revision surgery in 73 patien...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of shoulder and elbow surgery
دوره 17 6 شماره
صفحات -
تاریخ انتشار 2008