BACKGROUND In clinical practice, the differentiation of glaucomatous from non-glaucomatous cupping can be difficult, even for experienced observers. The purpose of this study was to evaluate the role of optical coherence tomography (OCT) in differentiating glaucomatous from non-glaucomatous optic nerve cupping in a cross-sectional pilot study. METHODS Eleven consecutive patients presenting to the Duke Eye Center from September 2007 to July 2008 with non-glaucomatous optic nerve cupping and 12 patients with glaucomatous optic nerve cupping were identified. All patients underwent Stratus® OCT imaging: fast macular map, fast retinal nerve fiber layer (RNFL) 3.4 thickness, and fast optic disc protocols. Automated visual field perimetry was performed on the date of OCT scan in non-glaucomatous cupping patients, and from 0-9 months of scan date in glaucoma patients. Eyes were matched by optic nerve cup-to-disc area ratio; average and mean deviation were calculated for each variable. RESULTS For a similar average RNFL, patients with non-glaucomatous optic nerve cupping had lower nasal and temporal RNFL thickness, as well as lower macular thickness and volume compared to patients with glaucomatous optic nerve cupping. CONCLUSION OCT appears to be a useful technology in differentiating glaucomatous from non-glaucomatous optic nerve cupping. The pattern of RNFL loss appears more diffuse in non-glaucomatous optic nerve cupping compared to glaucomatous optic nerve cupping. Future studies with larger sample size and specific neuro-ophthalmic causes of optic nerve cupping may further elucidate the role of OCT in this clinical setting.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Eyes with Large Disc Cupping and Normal Intraocular Pressure: Using Optical Coherence Tomography to Discriminate Those With and Without Glaucoma

We evaluated the ability of spectral-domain optic coherence tomography (SD-OCT) to differentiate large physiological optic disc cupping (LPC) from glaucomatous cupping in eyes with intraocular pressure (IOP) within the normal range. We prospectively enrolled patients with glaucoma or presumed LPC. Participants had optic discs with confirmed or suspected glaucomatous damage (defined as a vertica...

متن کامل

Detection of psychophysical and structural injury in eyes with glaucomatous optic neuropathy and normal standard automated perimetry.

OBJECTIVE To compare the prevalence of structural and psychophysical abnormalities in normal eyes and eyes with glaucomatous optic neuropathy (GON) and normal standard automated perimetry (SAP). METHODS Complete examination, SAP, short-wavelength automated perimetry (SWAP), frequency doubling technology (FDT), scanning laser polarimetry (GDx-VCC), and optical coherence tomography (OCT) of the...

متن کامل

Utility of optical coherence tomography angiography in detecting glaucomatous damage in a uveitic patient with disc congestion: A case report

Purpose To report a case of uveitic glaucoma with a congested optic disc where optical coherence tomography angiography (OCT-A) provided diagnostic utility in assessing glaucomatous damage but optical coherence tomography (OCT) alone had limited utility. Observations We report a case of a 33-year-old Caucasian female referred to the USC Roski Eye Institute for uncontrolled intraocular pressur...

متن کامل

Comparison of glaucomatous parameters in normal, ocular hypertensive and glaucomatous eyes using optical coherence tomography 3000.

This study was performed to evaluate optic disc appearance, retinal nerve fiber layer (RNFL) thickness, and macular thickness in normal, ocular hypertensive (OHT) and glaucomatous eyes using optical coherence tomography (OCT) 3000. One hundred fifty-eight eyes of 167 consecutive subjects were enrolled: 60 normal, 53 OHT, and 54 glaucomatous. OCT topographic parameters of cup diameter, cup area,...

متن کامل

Clinical distinction between nasal optic disc hypoplasia (NOH) and glaucoma with NOH-like temporal visual field defects

PURPOSE To report on the clinically important differences between nasal optic hypoplasia (NOH) and glaucoma with NOH-like temporal visual field defect (VFD). METHOD Five NOH (four bilateral and one unilateral) patients, three unilateral NOH patients with glaucoma, and two glaucoma patients with NOH-like temporal VFD were clinically characterized. Superior segmental optic nerve hypoplasia was ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2011