Voluven, a new colloid solution.

نویسندگان

  • Anna Mizzi
  • Thanh Tran
  • Rachel Karlnoski
  • Ashley Anderson
  • Devanand Mangar
  • Enrico M Camporesi
چکیده

Hydroxyethyl starch (HES) 130/0.4 (Voluven, Fresenius/Hospira, Germany) is indicated for the treatment and prophylaxis of hypovolemia. As the Voluven molecule is smaller than those of other available hydroxyethyl starch products, it is associated with less plasma accumulation and can be safely used in patients with renal impairment. Previous studies have demonstrated that Voluven has comparable effects on volume expansion and hemodynamics as other available HES products. Voluven is also associated with fewer effects on coagulation and may be an acceptable alternative to albumin for volume expansion in situations in which other starches are contraindicated secondary to risk of coagulopathy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Colloid versus Crystalloid Administration of Cardiopul- monary Bypass Prime Solution on Tissue and Organ Perfusion

Correspondence: D Zeighami Anesthesia ward, Faghihi Hospital, Zand Ave. Shiraz, Iran. Cell: +98-9173172580 Email: [email protected] Background: We evaluated the effects of tissue and organ perfusion during and after coronary artery bypass graft surgery with either colloid (Voluven) or crystalloid (Lactated ringer’s) as prime solution. Methods: In this prospective randomized-controlled trial ...

متن کامل

Distinctive effect of 6% hydroxyethyl starch 130/0.4 (Voluven) infusion on pediatric patients with congenital heart disease.

OBJECTIVE It has not been clear that Voluven (6% hydroxyethyl starch 130/0.4) may be administered in pediatric patients safely. The purpose of this study was to determine if Voluven could be used for blood volume expansion and hypovolemia prevention in pediatric patients with congenital heart disease. PATIENTS AND METHODS 50 pediatric patients with congenital heart disease were recruited in t...

متن کامل

[Thromboelastographic characteristics of different infusion therapy regimens in healthy bone marrow donors].

Infusion solutions are able to change the hemostatic system. Thromboelastography (TEG) is an integral technique to evaluate the hemostatic system. TEG was used to evaluate the effect of three infusion solutions (6% hydroxyexyethyl starch (HES) 200/0.5 - Hemohes; HES 130/0.4 - Voluven; modified gelatin solution - Gelofusin) on the hemostatic system in 36 bone marrow donors (healthy individuals)....

متن کامل

Perioperative clinical and economic outcomes associated with replacing first-generation high molecular weight hydroxyethyl starch (Hextend®) with low molecular weight hydroxyethyl starch (Voluven®) at a large medical center

BACKGROUND Several plasma volume expander alternatives exist to enhance intravascular volume status in patients undergoing surgery. The optimal intravascular volume expander in the perioperative setting is currently unknown. Low molecular weight hetastarch, Voluven® (130/0.4), may have a better safety profile than high molecular weight hetastarch, Hextend® (450/0.7). We examined the clinical an...

متن کامل

Comparison of the Effect of Voluven and Ringer Solution in Cardiopulmonary Bypass on the Bleeding After the Surgery and Renal Function in Coronary Artery Bypass Graft Surgeries

Background: This study compared the effect of Voluven and Ringer solution in cardiopulmonary bypass on the bleeding after the surgery and renal function in coronary artery bypass graft surgeries. Methods: Two types of prime solution including ringer - as Crystalloid- and Voluven were used in two groups and compared in terms of bleeding and renal function during the first 24 hours after the surg...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology clinics

دوره 29 3  شماره 

صفحات  -

تاریخ انتشار 2011