H ∞ Control of the Neutral Point in Four - Wire Three - Phase DC – AC
نویسنده
چکیده
Inverters used as the interface for a distributed generator in a three-phase four-wire system sometimes operate with a large neutral current because of unbalanced loads and singlephase (possibly nonlinear) loads. Voltage balance within the dc-link of the inverter is important for proper operation of the inverter, and the neutral current is a significant disturbance to this. It is preferable to use fast acting control rather than dissipative balancing or large-valued capacitors. This paper develops a linear model of an actively balanced split dc-link and applies H∞ control design to provide high-bandwidth robust control. The approach is developed for a conventional two-level inverter, but it remains valid (without change) for a three-level neutral-point clamped inverter. The controller achieves very small deviations of the neutral point (better than 0.5 in 800 V) from the midpoint of the dc source despite the large neutral current (32 ARMS). The controller design is described and verified first in a PSCAD simulation and second in experimental testing of a 30-kW 415-V (line) inverter.
منابع مشابه
Neural Network Implementation of a Three Phase Regulated PWM AC to Dc Convener with Input Unbalance Correction
Under unbalanced supply condition low order harmonics will appear at the input and output terminals of the PWM AC to DC converter. Based on the positive and negative sequence components, an unbalanced transfer matrix in terms of the input phase voltages is derived. An on-line method using a neural network (NN) is used to implement this transfer matrix. It is shown that by using an additional lo...
متن کاملHybrid direct power/current control using feedback linearization of three-level four-leg voltage source shunt active power filter
Introduction The excessive use of power electronic equipments, which represent nonlinear loads, in a distribution network has caused many disturbances in the quality of power such as harmonic pollutions, unbalanced load currents, and reactive power problems. As a result poor power factor, weakening efficiency, overheating of motors and transformers, malfunction of sensitive devices etc. are enc...
متن کاملImproving the performance of UPQC under unbalanced and distortional load conditions: A new control method
This paper presents a new control method for a three-phase four-wire Unified Power Quality Conditioner (UPQC) to deal with the problems of power quality under distortional and unbalanced load conditions. The proposed control approach is the combination of instantaneous power theory and Synchronous Reference Frame (SRF) theory which is optimized by using a self-tuning filter (STF) and without us...
متن کاملA Hybrid Control Method for Stable Operation of Active Power Filters in Three-Phase Four-Wire Networks
The main goal of this study is the use of Lyapunov’s stability theory to a three-phase four-wire shunt active power filter (SAPF), since this method has been applied effectively to other areas of converter. The dynamic model of the SAPF is first established, after that, a combination of fuzzy tracking control and Lyapunov function is suggested in order to impose a desired transient waveform on ...
متن کاملUPQC for Power Quality Improvement of Induction Motor Drive with Reduced DC Link Voltage
The main aim of this project is ,this topology enables UPQC to have a reduced dc-link voltage without compromising its compensation capability. Three-phase, four-wire unified Power Quality (UPQC) to improve power quality. The UPQC is realized by the integration of series and shunt active power filters (APF) sharing a common dc bus capacitor. The realization of shunt APF is carried out using a t...
متن کامل