Is a Precise Distortion Estimation Needed for Computer Aided Celiac Disease Diagnosis?

نویسندگان

  • Michael Gadermayr
  • Andreas Uhl
  • Andreas Vécsei
چکیده

In computer aided celiac disease diagnosis, endoscopes with wide-angle lenses are deployed which induce significant lens distortions. This work investigates an approach to automatize the estimation of the lens distortion, without a previous camera calibration. Knowing the discriminative power of all sensible distortion configurations, the model parameters are estimated. As the achieved parameters are not highly precise, moreover, we investigate the effect of approximative distortion correction on the classification accuracy. Particularly, we identify one simple but especially for certain features highly effective approximative distortion model.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A CAD System Framework for the Automatic Diagnosis and Annotation of Histological and Bone Marrow Images

Due to ever increasing of medical images data in the world’s medical centers and recent developments in hardware and technology of medical imaging, necessity of medical data software analysis is needed. Equipping medical science with intelligent tools in diagnosis and treatment of illnesses has resulted in reduction of physicians’ errors and physical and financial damages. In this article we pr...

متن کامل

Problems in Distortion Corrected Texture Classification and the Impact of Scale and Interpolation

In the field of computer aided celiac disease diagnosis, wide-angle endoscopy lenses are employed which introduce significant barrel type distortions. Although the images can be rectified using distortion correction methods, computer based diagnosis suffers from missing information in highly distorted image regions. First, we investigate the impact of simple and advanced interpolation technique...

متن کامل

Feature Extraction with Intrinsic Distortion Correction in Celiac Disease Imagery: No Need for Rasterization

In the fields of computer aided celiac disease diagnosis, wideangle endoscopy lenses are employed which introduce a significant degree of barrel type distortion. In recent studies on celiac disease classification, distortion correction techniques are investigated which use interpolation techniques, in order to maintain the rasterization of the image. Subsequent feature extraction is based on th...

متن کامل

Refractory Celiac Disease

Refractory celiac disease (RCD) is when malabsorption symptoms and villous atrophy persist despite strict adherence to a gluten free diet (GFD) for more than 12 months and other causes of villous atrophy have been ruled out.  RCD is considered a rare disease and almost exclusively occurs in adults. Persistent diarrhea, abdominal pain, weight loss are the most common symptoms in RCD. Also, anemi...

متن کامل

Distortion Adaptive Image Classification - An Alternative to Barrel-Type Distortion Correction

The endoscopes, utilized in computer aided celiac disease diagnosis are equipped with wide-angle lenses, which introduce significant barrel-type distortions. Previous work is on rectifying the distortions prior to the feature extraction. However, due to new arising inadequacies this often even decreases the classification accuracy. The idea of this paper is based on the fact, that there is a co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014