We evaluated the EMIT (enzyme-multiplied immuno technique) and FPIA (fluorescence polarization immunoassay) urine screening systems for detection of benzodiazepine intake. Healthy male volunteers were given single oral therapeutic doses of alprazolam (2 mg), chlordiazepoxide (25 mg), flunitrazepam (1 mg), lorazepam (3.75 mg), nitrazepam (5 mg), and triazolam (0.25 mg), after which urine was collected for the next 32 h. The EMIT method failed to detect the intake of flunitrazepam, lorazepam, and nitrazepam. FPIA did not detect the intake of chlordiazepoxide, flunitrazepam, lorazepam, nitrazepam, and triazolam. Modification of the EMIT method to include enzymatic hydrolysis did not significantly alter the results obtained with this method. A modification of the FPIA method to include enzymatic hydrolysis and a lower cutoff value improved the results considerably, so that we reliably detected all studied substances but flunitrazepam. We conclude that (a) both EMIT and FPIA techniques, when used as intended by the manufacturers, are unreliable for the detection of intake of therapeutic doses of these benzodiazepines, and (b) the described modification of the FPIA should provide a much improved tool for detection of benzodiazepine intake.
منابع مشابه
Table 1. Basal Serum, Urine, and Salivary Cortisol Concentrations (nmol/L) In the Groups Studied and after Dexamethasone (DXM) Suppression Tests In Patients with Cushing Syndrome
CLINICAL CHEMISTRY, Vol. 39, No. 6, 1993 1353 Odelius G, Wirbing P. Detection of benzodiazepine intake in therapeutic doses by immunoanalysis of urine: two techniques evaluated and modified for improved performance. Cbs Chem 1992;38:271-5. 3. Fraser AD. The benzodiazepines: a controversial class of drugs in the 1990s. Washington, DC: AACC la-Service Training and Continuing Education, 1992; 13(1...
متن کاملElectroanalytical Determination of Gemifloxacin Mesylate in Bulk, Tablets and Human Urine Using Gold Nanoparticles Modified Carbon Paste Electrode
A simple, precise, inexpensive and sensitive voltammetric method has been developed for the determination of gemifloxacin mesylate (GEM) in the presence of tween 80 in the bulk, farmaceutical dosage forms and human urine at gold nanoparticles modified carbon paste electrode (GNCPE). The electrochemical behavior of GEM has been investigated by using cyclic voltammetry (CV) and differential pulse...
متن کاملآشکارسازی تقلبهای منجر به پاسخهای منفی کاذب در آزمایش تشخیص اعتیاد
Background: Drug abusers are persistently trying to use masking techniques for hiding their addiction. Detection of false negative results of urine morphine test which caused by adulterants is the main goal of this study. Materials and methods: Screening test for detecting urine morphine was done by two kinds of Immuno-chromatography rapid tests and the positive results confirmation done by TL...
متن کاملA Sensitive Electrochemical Sensor for Determination of Imipramine in Urine Sample Using Carbon Ionic Liquid Electrode Modified With Montomorillonite Nanoclay
We used an effective electrochemical sensor for the determination of imipramine at pH 7.2 using a carbon nanocomposite electrode. The electrode has been designed by incorporation of montmorillonite nanoclay into the carbon ionic liquid electrode. The high sensitivity of 1.714 μA (μM)-1, two linear calibration ranges of 0.1–2 μM and 2-40 μM, and detection limit of 19 nM were achieved. The relati...
متن کاملDetermination of Two Antiepileptic Drugs in Urine by Homogenous Liquid-Liquid Extraction Performed in A Narrow Tube Combined With Dispersive Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection
A simple and efficient homogenous liquid-liquid extraction method performed in a narrow tube combined with dispersive liquid-liquid microextraction method has been presented for the simultaneous determination of two antiepileptic drugs in urine followed by gas chromatography with flame ionization detection. In this method, a mixture of acetonitrile and urine sample (homogenous solution) is load...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 38 2 شماره
صفحات -
تاریخ انتشار 1992