Considerations for standard chest radiography: the long film-focus distance technique.

نویسندگان

  • M Hirose
  • M Ikeda
  • K Ito
  • T Ishigaki
  • S Sakuma
چکیده

The possibility of using long film-focus distance radiography as a new screening method for lung cancer diagnosis was investigated. Long-film focus distance radiography produced exceptionally superior image sharpness suitable for use as clinical photographs, at a distance of about FFD (Film-Focus Distance) 20 m. The effective energy was increased by narrowing the radiation spectrum via an air-filter effect, which may prove useful in reducing radiation exposure dosage. Questionnaire results indicate good visualization of cardiac posterior and trachea shadow regions in the diaphragm. Further study is required regarding methods for stabilizing patient position and synchronization with heart beat and respiration to improve reproducibility.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Efficacy of Increasing Focus to Film Distance (FFD) for Patient’s Dose and Image Quality in Pediatric Chest Radiography

Background: Increasing the x-ray focus to film distance (FFD) has been advocated as an effective method to reduce the patients’ radiation dose. The aim of this study was to investigate the efficacy of this technique in patients' dose and image quality in pediatric chest x-ray.Material and methods: Sixty pediatric patients were x-ray imaged at FFDs of 100 and 130 cm. Dose measurements were perfo...

متن کامل

Optimization of Radiological Protection in Pediatric Patients Undergoing Common Conventional Radiological Procedures: Effectiveness of Increasing the Film to Focus Distance (FFD)

Background Increasing the x-ray film to focus distance (FFD), has been recommended as a practical dose optimization tool for patients undergoing conventional radiological procedures. In the previous study, we demonstrated a 32% reduction in absorbed dose is achievable due to increasing the FFD from 100 to 130 cm during pediatric chest radiography. The aim of this study was to examine whether in...

متن کامل

Compliance of Radiation Dose and Image Quality in a Nigerian Teaching Hospital with the European Guidelines for Pediatric Screen-Film Chest Radiography

Introduction Blue light is a part of the spectrum with the highest energy content, which can reach the retina. The damage that it can cause to the retina is called photochemical or blue-light retinal injury. For the retinal injury assessment of the photochemical and aphakic retinal hazards in the wavelength range of 300-700 nm, use of effective spectral radiance limits (W.m-2.sr-1) seems to be...

متن کامل

A Phantom Study for the Optimization of Image Quality and Radiation Dose for Common Radiographic Examinations in Digital Radiography

Introduction: Phantom studies facilitate the implementation of radiation dose surveillance as a function of radiographic technical parameters for minimizing patient radiation dose. The evidence of such investigations can then be used to evaluate technical parameters used in the radiographic procedures to reduce radiation dose without compromising the image quality. Material and Methods: This ex...

متن کامل

The use of EBT3 film and Delta4 for the dosimetric verification of EclipseTM treatment planning system in a heterogeneous chest phantom: an IMRT technique

Background: This study aimed to evaluate the dose calculation accuracy of EclipseTM treatment planning system (TPS) in a heterogeneous chest phantom with the intensity modulated radiotherapy (IMRT) technique using EBT3 film and Delta4. Materials and Methods: Two IMRT plans (A and B) were prepared for radiotherapy of the heterogeneous chest phantom. Plan A was between the left lung and the surro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Nagoya journal of medical science

دوره 55 1-4  شماره 

صفحات  -

تاریخ انتشار 1993