[Development of a Lead-covered Case for a Wireless X-ray Output Analyzer to Perform CT Half-value Layer Measurements].

نویسندگان

  • Hirokazu Akaishi
  • Hiromitsu Takeda
  • Yoshiyuki Kanazawa
  • Yuji Yoshii
  • Osamu Asanuma
چکیده

Measurement of the half-value layer (HVL) is a difficult task in computed tomography (CT) , because a nonrotating X-ray tube must be used. The purpose of this study is to develop a lead-covered case, which enables HVL measurements with a rotating CT X-ray tube. The lead-covered case was manufactured from acrylic and lead plates, which are 3 mm thick and have a slit. The slit-detector distance can be selected between 14 mm and 122 mm. HVL measurements were performed using a wireless X-ray output analyzer "Piranha." We used the following exposure conditions: tube voltages of 80, 100, and 120 kV; a tube current of 550 mA; and an exposure time of 1.0 s. The HVLs were measured by using the following two methods: (a) Nonrotating method-a conventional method that uses the nonrotating exposure mode. (b) Rotating method-a new method that uses the lead-covered case and the rotating exposure mode. As a result, when the slit-detector distance was 58 mm, the HVL values obtained by the nonrotating and rotating methods were 4.38 and 4.24 mmAl at 80 kV, 5.51 and 5.37 mmAl at 100 kV, 6.61 and 6.48 mmAl at 120 kV, respectively. A lead-covered case, which enables the measurement of the HVL in a rotating X-ray tube, was developed. The case is useful in measuring the HVLs at facilities that cannot fix the X-ray tube.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of measuring half‐ and quarter‐value layers and appropriate aperture width of a convenient method using a lead‐covered case in X‐ray computed tomography

Determination of the half-value layer (HVL) and quarter-value layer (QVL) values is not an easy task in x-ray computed tomography (CT), because a nonrotating x-ray tube must be used, which requires the assistance of service engineers. Therefore, in this study, we determined the accuracy of the lead-covered case method, which uses x-rays from a rotating x-ray tube, for measuring the HVL and QVL ...

متن کامل

Evaluation of a systemic change of Superficial X-ray tube characteristics

Introduction: Very low, Low and Medium X-ray machines are used extensively for Superficial Radiation Therapy mostly used for Basal Cell, Squamous Cell Carcinoma, and Melanoma skin cancers. In most of cases, Superficial X-ray Therapy (SXRT) is preferred to Electron beams generated using a linear accelerator. SXRT tube characteristics may vary with the use of the machine for a lo...

متن کامل

Evaluation of the Quality Control Program for Diagnostic Radiography and Fluoroscopy Devices in Syria during 2005-2013

Introduction: Extensive use of diagnostic radiology is the largest contributor to total population radiation doses. Thus, appropriate equipment and safe practice are necessary for good-quality images with optimal doses. This study aimed to perform quality control (QC) audit for radiography and fluoroscopy devices owned by private sector in Syria (2005-2013) to verify compliance of performance o...

متن کامل

Characteristics of lead glass for radiation protection purposes: A Monte Carlo study

Background: Lead glass has a wide variety of applications in radiation protection. This study aims to investigate some characteristics of lead glass such as the γ-ray energy-dependent mass and linear attenuation coefficients, the half-value layer thickness, and the absorbed dose distribution for specific energy. Materials and Methods: The attenuation parameters of different lead glass types aga...

متن کامل

Investigation of the Mass Attenuation Coefficient for Composites Containing Nano and Micro-Particles of Copper Oxide against Diagnostic X-ray

Radiation protection and the selection of suitable materials to reduce radiation effects is one of the important branches of medical science and radiation. In this paper, the mass attenuation coefficients, half value layer thicknesses and thicknesses of 0/5 mm lead of polyvinyl chloride (PVC) composites containing Nano and micro-particles of copper oxide are calculated using experimental method...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nihon Hoshasen Gijutsu Gakkai zasshi

دوره 72 3  شماره 

صفحات  -

تاریخ انتشار 2016