High-sensitivity radiation detector for low dose level radiological applications
نویسندگان
چکیده
Radiation dosimetry by Fricke gel was largely used, generally focused and optimized for radiotherapy applications therefore involving relative high dose levels. Fricke gel dosimetry has several advantages, like dose rate and LET almost independence, 3D mapping, among other. This work presents a novel Fricke gel dosimeter optimized for low dose levels. Several chemical composition were studied varying concentrations of sulfuric acid (H2SO4), ferrous ammonium sulphate ((NH4)2Fe(SO4)2 · 6H2O), benzoic acid (C7H6O2) and Xylenol orange (C31H32N2O13S). Samples were analyzed by light transmission and absorbance. Sensitivity for low dose levels was significantly improved testing typical radiology setups. Comparisons with ionization chamber showed good agreement. Thus, remarking reliability of the developed system as promising tool for low-level dosimetry.
منابع مشابه
Absorbed dose to peripheral organs during different methods of dental radiology using radiation estimation models
Introduction: Dental radiography as one of the most frequent type of radiological examinations is accepted for medical investigations due to their significant benefits nevertheless using ionizing radiation. It has lower radiation dose compared to another radiological examination but because of its high application for children, radiation dose needs attention. Based on affectin...
متن کاملPhoton dosimetry based on selective data sampling for the NaI(TL) detector
Radiation detection is essential for determining of radiation dose. Depend on the detector and dosimetry method, detection process is performed in different levels. Pulse counting is the first level of detection. Typically, the output of a radiation detector for determining value of the radiation dose cannot be used directly. Through changing the response function or the readout detector, is tr...
متن کاملStudy of the Radiological Doses in Karbala city
Background: Man-made radionuclides, which are present in environment, have been created by human activities and added to the inventory of natural radionuclides for example 3H, 131I, 129I, 137Cs, 90Sr and 239Pu, in spite of the amount added is little compared to natural quantities. The aim of this study is to estimate the levels of radiological doses in the soil samples collected from different...
متن کاملTrabecular bone changes induced by fast neutrons versus gamma rays in mice
Background: The trabecular bone changes in the tibia of C3H/HeN mice were measured 12 weeks after whole body irradiation with various doses of fast neutrons (0-2.4 Gy) or 137Cs-generated gamma-rays (0-6 Gy). Materials and Methods: Serum calcium, phosphorus, estradiol concentration and alkaline phosphatase activity were measured. Tibiae were anal...
متن کاملمروری بر حفاظت در برابر پرتو در رادیولوژی تشخیصی
Discovery of x-ray and using of it for medical imaging have produced tremendous outcomes for diagnosis and treatment of diseases. More than 10 million diagnostic radiological procedures and 100,000 nuclear medicine exams are being performed daily around the world. According to the national commission on radiological protection and measurements (NCRP)-report 160, medical x-ray is contribute to a...
متن کامل